^aceAnalytical Method 8290 Analysis Results
Tai: 612-607-1700
Frx' «12. 6C7-K44.4
Client - ATC
Client’s Sample ID ATC-0427-STY>DX23
Lab Sample ID 103513453
Filename F20524A_10
Injected By MRO
Total Amount Extracted 0.04 3 Matrix DUST
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 04/27/2002
ICAL Date 05/04/2002 Received 05/01/2002
CCal Filename(s) F20524A_01 & F20524A_15 Extracted 05/20/2002
Method Blank ID BLANK-1633 Analyzed 05/24/2002 16:37
Native Cone EMPC LRU Internal ng's Percent
Isomers ng/Kg ng/Kg ng/Kg Standards Added Recovery
2,3,7,8-TCDF ND 50 2,3,7,8-TCDF-13C 2.00 82
Total TCDF 200 50 J 2,3,7,8-TCDD-13C 2.00 83
1,2,3,7.8-PeCDF-l3C 2.00 74
2,3,7,8-TCDD ND 50 2,3,4,7,8.peCDF-13C 2.00 73
Total TCDD 190 50 BJ 1,2,3,7,8-PeCDD-13C 2.00 78
1.2.3.4,7,8-HxCDF-13C 2.00 68
1,2,3,7,8-PeCDF ND 250 1,2,3,6,7.8-HxCDF-13C 2.00 79
2,3,4,7.8-PeCDF ND 250 2,3,4,6.7,8-HxCDF-13C 2.00 79
Total PeCDF ND 250 1,2,3,7,8,9-HxCDF-13C 2.00 68
1,2,3,4.7,8-HxCDD-13C 2.00 81
1,2,3,7,8-P8CDD ND 250 1,2,3,6,7,8-HxCDD-13C 2,00 92
Total PeCDD ND 250 1,2,3,4,6,7,a-HpCDF-13C 2.00 62
1,2,3,4,7,8,9-HpCDF-13C 2.00 44
1,2.3,4,7.8-HxCDF ND 250 1,2,3.4,6,7,8-HpCDD-13C 2.00 46
1,2.3,6,7,8-HxCDF ND 250 OCDD-13C 4.00 45
2,3,4.6.7,8-HxCDF NO 250
1,2,3,7,8,g-HxCDF ND 250 1.2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 250 1,2,3.7.8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8.HxCDD ND 250 2,3,7,8-TCDD-37C14 0.20 85
1,2,3,6.7,8-HxCDD ND 250
1,2,3.7.8,9-HxCDD ND 250
Total HxCDD 350 250 J
1,2.3,4,6,7,8-HpCDF ND 250 Total 2,3,7.8-TCDD
1,2,3,4.7,8,9-HpCDF ND 250 Equivalence: 6.0 ng/Kg
Total HpCDF ND 250 (Using ITE Factors)
1,2,3,4,6,7.8-HpCDD 360 250 J
Total HpCDD 840 250 J
OCDF ND 500
OCDD 2400 500 BJ
Results reported on a total weight basis LRL = Lower Reporting Limit
Cone a Concentration (Totals Include 2,3,7,S-sutJstituted isomers) I B Interference
EMPC B Estimaiad Maximum Possible Concentration E » PCDP Interference
A s Detection Limit based on sianal-to-noisa measurement S = Saturated signal
J = Concentration detected is below Bio calibration range ND = Not Detected
B s Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC = Not Calculated
Nn a Value obtained from additional analysis • = See Discussion
Report No.... 02-1057132