^ace Analytical Method 8290 Analysis Results
Tel; 612-607-170Q
Fay SI 2- I5n7-Sdxi
Client ■ ATC
Client’s Sample ID ATC-0427-STY-DX23
Lab Sample ID 103513453
Filename F20524A_10
Injected By MRO
Total Amount Extracted 0.04 g Matrix DUST
% Moisture NA Dilution NA
Dry Weight Extracted NA Ccllectsd 04/27/2002
ICAL Date 05/04/2002 Received 05/01/2002
CCal Filename{s) F20524A_01 &F20524A_15 Extracted 05/20/2002
Method Blank ID BLANK-1633 Analyzed 05/24/2002 16:37
Native Cone EMPC LRL Internal ng’s Percent
Isomers ng/Kg ng/Kg ng/Kg Standards Added Recovery
2,3.7,S-TCDF ND 50 2,3,7.3-TCDF-13C 2.00 82
Total TCDF 200 SO J 2,3,7,3-TCDD-13C 2.00 83
1,2,3,7.8-PeCDF-13C 2.00 74
2.3,7,8-TCDD ND 50 2,3,4,7,8-PeCDF-13C 2.00 73
Total TCDD 190 50 BJ 1.2,3,7,a-PeCDD-13C 2.00 78
1.2,3,4,7,8-HxCDF-13C 2.00 68
1,2,3,7,8-PeCDF ND 250 1,2,3.S.7,8-HxCDF-13C 2.00 79
2,3,4,7,a-PeCDF ND 250 2,3,4,6,7,5-HxCDF-13C 2.00 79
Total PeCDF ND 250 1,2,3,7,8,9-HxCDF-13C 2.00 68
1,2,3,4.7,8-HxCDD-13C 2.00 81
1,2.3,7,S-PeCDD ND 250 1.2,3,6,7.8-HxCDD-13C 2.00 92
Total PeCDD ND 250 1,2,3,4,6,7,8-HpCDF-13C 2.00 62
1.2.3,4,7.8,9-HpCDF-13C 2.00 44
1,2,3,4,7.8-HxCDF ND 250 1,2,3,4,S.7,8-HpCDD-13C 2.00 46
1,2,3,6,7,8-HxCDF ND 250 OCDD-13C 4.00 45
2,3,4,6.7,8-HxCDF ND 250
1,2,3,7,8,9-HxCDF ND 250 1,2.3.4-TCDD-13C 2.00 NA
Total HxCDF ND 250 1,2.3,7.8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 250 2,3,7,8-TCDD-37Ct4 0.20 85
1,2,3,6,7,8-HxCDD ND 250
1.2.3,7,8,9-HxCDD ND 250
Total HxCDD 350 250 J
1,2,3,4,6,7,8-HpCDF ND 250 Total 2,3,7,8-TCDD
1,2,3,4.7,8,9-HdCDF ND 250 Equivalence; 6.0 ng/Kg
Total HpCDF ND 250 (Using ITE Factors')
1,2.3,4.6,7.8-HpCDD 360 250 J
Total HpCDD 840 250 J
OCDF ND 500
OCDD 2400 500 BJ
Results reported on a total weight basis LRL = Lower Reporting Limit
Cone = Concentration (Totals Include 2.3,7,8-sutststuted isomers) 1 3 Interference
£.\4PC = Estimatad Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signai-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
a = Lass than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of arget range NC = Not Calculated
Nn n Value obtained from additional analysis ■ = See Discussion
Report No.... 02-1057132
REPORT OF LABORATORY ANALYS3S
This report snail not ba raproducad, except in full,
without the written consent of Pace Analytical Se(\lcas, Inc.