weAnalyticar_________ Method 8290 Analysis Results
Tel: 612-607-170C
Frx- 612-
Client - ATC
Clienrs Sample ID ATC-0427-STY-0X21
Lab Sample ID 103513438
Filename F20524A_08
Injected By MRO
Total Amount Extracted 0.13 g Matrix DUST
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 04/27/2002
ICAL Date 05/04/2002 Received 05/01/2002
CCal Filename(s) F2O524AL.01 & F20524A 15 Extracted 05/20/2002
Method Blank ID BLANK-1633 Analyzed 05/24/2002 14:58
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/Kg ng/Kg ng/Kg Standards Added Recovery
2,3.7,8-TCDF 35 15.0 J 2,3,7,8-TCDF.13C 2.00 75
Total TCDF 790 ----- 15.0 2,3,7,8-TCDD-13C 2.00 74
1,2.3,7,8-PeCDF-13C 2.00 70
2,3,7,8-TCDD ND 16.0 A 2,3,4,7,8-P©CDF-13C 2.00 69
Total TCDD 520 15.0 1,2,3,7.8-PeCDD-13C 2.00 73
1,2,3,4,7,8-HxCDF-13C 2.00 77
1,2,3,7,a-PeCDF ND 77.0 1,2.3,6,7,8-HXCDF-13C 2.00 39
2,3,4,7,e-P0CDF ND 77.0 2.3,4,6,7,a-HxCDF-13C 2.C0 87
Total PeCDF 190 77.0 J 1,2,3.7,8,9-HxCDF-13C 2.00 86
1,2,3,4,7,a-HxCDD-13C 2.00 90
1,2,3.7,8-PeCDD ND 77.0 1,2,3.6,7,8-HxCDD-13C 2.00 93
Total PeCDD 200 77.0 J 1,2,3.4,6,7,8-HpCDF-13C 2.00 77
1,2,3,4,7,8,9-HpCDF-13C 2.00 51
1,2,3,4,7,8-HxCDF 87 77.0 E 1.2,3,4,B,7.8-HpCDD-13C 2.00 67
1,2,3,6,7,8-HxCDF ND 77.0 OCDD-13C 4.00 56
2,3,4,6,7,8-HxCDF ND 77.0
1,2,3,7,a,9-HxCDF ND 77.0 1,2,3.4-TCDD-13C 2.00 NA
Total HxCDF 130 77.0 J 1.2.3,7,8,9-HxCDD-13C 2.00 NA
1.2,3,4.7.8-HxCDD ND 77.0 2.3,7,8-TCDD-37CI4 0.20 78
1.2,3,6,7,8-HxCDD ND 77.0
1,2,3,7,8,9-HxCDD ND 77.0
Total HxCDD 410 77.0
1,2.3.4,6,7.8-HpCDF 200 77.0 J Total 2,3.7,8-TCDD
1.2,3.4,7.8.9-HpCDF ND 77.0 Equivalence: 13 ng/Kg
Total HpCDF 200 77.0 J {Using ITE Factors)
1.2.3,4,6.7,8-HpCDD 410 77.0
Total HpCDD 880 77-0
OCDF 270 150.0 J
OCDD 3100 150.0
Results reported on a total weight basis LRL = Lower Reporting Limit
Cone = Cancantration (Totals includa 2,3,7,8-$ubsntuta4 isomers) I = Interference
EMPC S3 Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signat-to-nolss measurement S s Saturated signal
J » Concsntratlon detected Is below the calibration range ND = Not Detected
B > Less than 10 limes higher than method blank level NA = Not Appticabla
P = Recovery outside of target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See DIscussitxi
Report No.... 02-1057132
REPORT OF LABORATORY ANALYSIS
This report shall not be repraducad. except in full,
without the written consent of Paco Analytical Services, Inc.
CITY_21MC1OO_OO2867962
NYC-WTC_000372573