NYC 9/11 Public Portal Document
1700 Bm Street-Suite 200
Minneapolis, MN 55414
TM
^aceAnalytical_________ Method 8290 Analysis Results
Tel: 512-607-1700
Fax- 61?- 807-6444
Client-ATC
diem’s Sample ID ATC-0427-STY-DX20
Lab Sample ID 103513420
Filename F20523A_ie
Injected By BAL
Total Amount Extracted 0.21 g Matrix DUST
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 04/27/2002
ICAL Data 05/04/2002 Received 05/01/2002
CCal Fllenams/s) F20523A_05 & F20523A_20 Extracted 05/20/2002
Method Blank ID BLANK-1633 Analyzed 05/24/2002 02:46
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/Kg ng/Kg ng/Kg Standards Added Recovery
2,3,7,B-TCDF 27 12.0 EA 2,3,7,8-TCDF-13C 2.00 84
Total TCDF 380 9.5 2,3,7,8-TCDD-13C 2.00 74
1.2,3,7.8-PeCDF-l3C 2.00 73
2,3,7,8-TCDD ND 13.0 A 2,3,4,7,8-PeCDF-13C 2.00 72
Total TCDD 850 9.5 1,2,3,7,8-PeCDD-13C 2.00 66
1,2,3,4,7,8-HxCDF-13C 2.00 77
1,2,3,7,8-PeCDF ND 48.0 1,2.3,6,7,a-HxCDF-13C 2.00 97
2,3,4,7.8-PeCDF 51 48.0 J 2,3,4.6,7,8-HxCDF-13C 2.00 93
Total PeCDF 350 48.0 1,2,3,7,8,9-HxCDF-13C 2.00 80
1,2,3,4,7,8-HxCDD-13C 2.00 85
1,2,3,7,8-PsCDD ND 48.0 1,2,3.6,7,8-HxCDD-13C 2.00 93
Total PeCDD 97 48.0 1,2,3,4.6.7,8-HpCDF-13C 2.00 62
1,2.3,4,7,8,9-HpCDF-13C 2.00 48
1,2,3,4,7,8-HxCDF 82 48.0 E 1,2,3,4,6,7,8-HpCDD-13C 2.00 45
1,2.3,6,7,8-HxCDF 66 48.0 E OCDD-13C 4.00 55
2,3,4,S,7,6-HxCDF 73 48.0 J
1,2,3,7.8,9-HxCDF ND 48.0 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF 440 48.0 1.2,3,7,B,9-HxCDD-13C 2.00 NA
1.2,3,4,7.8-HxCDD ND 48.0 2,3,7,8-TCDD-37Cl4 0.20 81
1.2,3,6,7,8-HxCDD 51 48.0 J
1,2,3,7,8,9-HxCDD ND 48.0
Total HxCDD 900 48.0
1.2,3,4.6,7,8-HpCDF 280 48.0 Total 2,3,7,8-TCDD
1,2,3,4.7,8,9.HpCDF ND 48.0 Equivalence: 51 ng/Kg
Total HpCDF 280 48.0 (Using ITE Factors)
1.2.3,4,6,7.B-HpCDD 600 48.0
Total HpCDD 1300 48.0
OCDF 410 95.0 J
OCDD 4200 95.0
Results reported on a total weight basis LRL = Lower Reporting Limit
Cone « Concentration (Totals include 2,3,7,8-substhuted isomers) I = Interference
EMPC a Estimated Maximum Possible Concentration E = PCDE Interference
A * Oelection Limit based on signal-to-noise measurement S 9 Saturated signal
J 9 Concentration detected is below ttie calibration range NO a Not Detected
B = Less than 10 times higher than method dank level NA = Not Applicable
P a Recovery outside of target range NC = Not Calculated
Nn » Value obtained from additional analysis ’ 9 See Discussion
Report No....02-1057132
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Paca Analytical Services, Inc.
CITY_21MC100_002867961
NYC-WTC_000372572
OCR can misread numbers and units. Confirm readings against the page image before using them.