^ace Analytical__________ Method 8290 Analysis Results
Tel; 612-607-1700
Fax; 612- 607-6444
Client - ATC
Clients Sample ID ATC-0427-STY-DX17
Lab Sample ID 103513396
Filename F20523A_15
Injected By BAL
Total Amount Extracted 0,02 g Matrix DUST
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 04/27/2002
iCALDate 05/04/2002 Received 05/01/2002
CCal FilenameCs) F20523A_05 & F20523A_20 Extracted 05/20/2002
Method Blank ID Bl-ANK-1633 Analyzed 05/24/2002 00:19
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/Kg ng/Kg ng/Kg Standards Added Recovery
2,3,7,8-TCDF 180 — 100 J 2,3,7,8-TCDF-13C 2.00 87
Total TCDF 2100 — 100 2,3,7,8-TCDD-13C 2.00 76
1.2,3,7,8-PeCDF-13C 2.00 76
2.3,7.8-TCDD ND 130 A 2,3,4,7,8-PgCDF-13C 2.00 76
Total TCDD 2800 100 1.2,3.7,8-PeCDD-13C 2.00 68
1,2,3,4,7,8-HxCDF-13C 2.00 87
1,2,3.7.8-PeCOF ND 500 1,2,3,6,7,8-HxCDF-13C 2.00 101
2,3,4,7,8-PeCDF ND 500 2,3,4,6,7,8'HxCDF-13C 2.00 97
Total PeCDF 510 500 J 1,2,3,7,8,9-HxCDF-13C 2.00 90
1.2,3.4.7,8-HxCDD-13C 2.00 85
1.2,3,7,8-PeCDD ND 500 1,2,3.e.7.8-HxCDD-13C 2.00 100
Total PeCDD 2300 500 J 1,2,3,4.6,7,8-HpCDF-13C 2.00 64
1,2,3,4.7,8,9-HpCDF-13C 2.00 60
1,2,3,4,7,a-HxCDF ND 500 1.2,3.4,6,7.8-HpCDD-l3C 2.00 45
1.2.3.6,7,8-HxCOF ND 500 OCDD-13C 4.00 53
2,3,4,6,7,8-HxCDF ND 500
1,2,3,7,8,9-HxCDF ND 500 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF 1000 500 J 1,2,3,7.8,9-HxCDD-13C 2.00 NA
1,2,3,4,7.8-HxCDD ND 500 2,3,7,8-TCDD-37CI4 0.20 80
1,2,3.6.7,8'HxCDD ND 500
1,2,3,7,8,9-HxCDD ND 500
Total HxCDD 6000 500
1,2,3,4,6,7.8'HpCOF 1500 500 J Total 2.3.7.8-TCDD
1.2.3.4,7,8,9-HpCDF ND 500 Equivalence; 69 ng/Kg
Total HpCDF 2200 500 J (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD 2500 500
Total HpCDD 5700 500
OCOF 1500 1000 J
OCDD 9300 1000 B
Results reported on a total weight basis LRL 3 Lower Reporting Limit
Cone s Concentration (TotalB include 2.3,7 .e-aubalituted feomora) 13 Interference
EMPC a: Estimated Maximum Possible Concentration E = PCDE Interference
A 3 Detection Limit based on signal-to-noise measurement S 3 Sswrated signal
J 3 Concentration detected ta below the calibration range ND = Not Detected
B 3 Lass than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside of target range NC 3 Not Caleulated
Nn 3 Value obtained from additional analysts • = See Discussion
Report No.... 02-1057132