104 East 25th S New York, New York 1001 www.atc-enviro.cor 212.353828 Fax 212 353.830 ASSOCIATES INC.
Mr. Bernard P. Orlan June 6, 2002 Page 2
2. IS 306X
A total of ten (10) dust wipe samples were collected from selected unit ventilators throughout the school. Laboratory analysis detected lead concentrations which ranged between 1,817.0- pg tf to 259.4 pg/ft". The average concentration was 806.38 pg- ftV
B. LEAD WIPE SAMPLING -HVAC UNITS
1. STUYVESANT HIGH SCHOOL
A total of fifteen (15) dust wipe samples were collected from various HVAC units throughout the school. Laboratory analysis detected lead concentrations which ranged between 253.0 pg/ft‘ to less than the limit of detection of 9.0 pg.Tty The average concentration was 89.16 pg/ft'.
IS 306X
A total of eighteen (18) dust wipe samples were collected from various HVAC units throughout the school. Laboratory analysis detected lead concentrations which ranged between 466.7 ug fT to 18.5 pg'ft\ The average concentration was 159.45 pg/ft^.
Exact sample locations and analytical laboratory results for the samples collected at each school is included in Appendix A of this report.
C. DIOXIN BULK SAMPLING - STUYVESANT HIGH SCHOOL
ATC collected twenty-four (24) samples for PCDDs/PCDFs (plus two blanks) within Unit Ventilators and HVAC units at Stuyvesant High School. All samples were submitted for laboratory analysis to Pace Analytical Services, Inc. (Pace) of Minneapolis, MN, a laboratory experienced in dioxin analysis. The analysis was performed by modified EPA Method 8290 using combined capillary column gas chromatography/high resolution mass spectrometry.
Each sample was analyzed for sixteen (16) PCDD/PCDF isomers. The results for each isomer were then converted to 2, 3, 7, 8 tetrachloro-dibenzo-p-dioxin (2, 3, 7, 8-TCDD) equivalents by multiplying by an established equivalency factor. This provides a single value for the analytical results for each sample.
CITY_21MC100_002867909
NYC-WTC_000372537
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000406367
ATC sampling report for environmental testing at Stuyvesant HS and IS 306X.
14 shared non-person entities · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241040
ATC memo summarizing environmental sampling at Stuyvesant HS and IS 306X, April 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000372600
ATC environmental sampling report for Stuyvesant HS including dust wipe collection (April 27, 2002).
13 shared non-person entities · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317244
ATC report covering environmental sampling and analysis at Stuyvesant HS.
13 shared non-person entities · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240982
Environmental sampling report at Stuyvesant High School, including dust wipes and bulk samples.
13 shared non-person entities · similarity 0.988
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321492
Environmental sampling report for dust and HVAC at Stuyvesant HS and IS 306X, Apr 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338659
Environmental sampling report for Stuyvesant HS and IS 306X conducted April 2002.
14 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321477
ATC report on environmental sampling at NYC schools including HVAC and lead/asbestos tests.
13 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000265069
June 6, 2002 NYC DOE environmental sampling report for Stuyvesant High School.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199874
Report documenting environmental sampling and HVAC testing conducted at specific New York City schools following requests from the Board of Education.
14 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000199782
Letter from ATC Associates to the NYC Board of Education regarding environmental and HVAC sampling at specific schools in June 2002.
14 shared non-person entities · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000437006
ATC Associates conducted lead dust wipe and asbestos/dioxin bulk sampling at Stuyvesant High School; reports dated Apr 2002.
13 shared non-person entities · similarity 0.987
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000406367
ATC sampling report for environmental testing at Stuyvesant HS and IS 306X.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321492
Environmental sampling report for dust and HVAC at Stuyvesant HS and IS 306X, Apr 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000241040
ATC memo summarizing environmental sampling at Stuyvesant HS and IS 306X, April 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000338659
Environmental sampling report for Stuyvesant HS and IS 306X conducted April 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321477
ATC report on environmental sampling at NYC schools including HVAC and lead/asbestos tests.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000265069
June 6, 2002 NYC DOE environmental sampling report for Stuyvesant High School.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000321492
Environmental sampling report for dust and HVAC at Stuyvesant HS and IS 306X, Apr 2002.
Similar indexed content
NYC-WTC_000338659
Environmental sampling report for Stuyvesant HS and IS 306X conducted April 2002.
Similar indexed content
NYC-WTC_000406367
ATC sampling report for environmental testing at Stuyvesant HS and IS 306X.
Similar indexed content
NYC-WTC_000241040
ATC memo summarizing environmental sampling at Stuyvesant HS and IS 306X, April 2002.
Similar indexed content
NYC-WTC_000321477
ATC report on environmental sampling at NYC schools including HVAC and lead/asbestos tests.
Similar indexed content