NYC 9/11 Public Portal Document
ATC Associates
104 East 25 Street, New York, NY 10010
Phone; (212) 353-8280 Fax: (212)353-8306
Attn: Mr. Bernard Orlan Received: 6/13/02 9:00:00 PM
N.Y.C. Board of Education ATC Group#: 8086
28-11 Queens Plaza North Analysis Date: 6/14/02
Long Island City, NY 11101
Fax: (212)475-4122 Phone: (212)477-8941
Project: NYC-BOE F'S 234M Project#: 14584-1823
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area Nau Asbestos a Structures Sensitivity CoHcentratioH
Sample Volume Analyzeel Asb Type(s) O.S/i-5 Sfi (S/CC) (S/mm^) (S/cc) Notes
01 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
8086 -I
02 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
8086 -2
03 1936.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
8086 -J
04 1920.00 0.9450 0 None Detected 0 0 0.0045 <22.24 <0.0045
8086 -4
05 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
8086 -J
06 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 <0.0044
8086 -6
07 1928.00 0.0450 0 None Detected 0 0 0.0044 <22.24 < 0.0044
S086 -7
MARK PEYSAKHOV MICHAEL A. GORYCKl, Ph.D.
^Approv^ by.
I
Disclaimer The laboratory is not responsible for data reported in structures/x, which is dependent on volume xllected by non-laboratory personnel. This labSs only responsible
for data reported in structures/mm’. This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim
prcxfuct endorsement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples repotted above. Quality control data (including 95%
confidence limits and laboratory and analysis' accuracy and precision) is available upon request
Accredited (or NVLAP PLMTEM #101187-0, NY State ELAP #10879
Page I of 2
CITY_21MC100_002852473
NYC-WTC_000372364
OCR can misread numbers and units. Confirm readings against the page image before using them.