NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

IAQ report, PS 234M, Apr 2002

Machine-extracted title · confidence 62%

ATC IAQ measurements report for PS 234M during April 2002.

NYC-WTC_000371833–000371836
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Mr. Bernard P. Orlan April 16,2002 Indoor Air Quality Assessment Page 3 LS^23.4M ATC Protect No. 15-19125-0279

Real-Time Environmental Measurements

ATC collected si.xty (60) sets of real-time environmental measurements consisting of fifty-one (51) from inside the school building and nine (9) outdoors. All three floors of the school were surveyed. These results are described below.

Field data sheets are found in Attachment 1. Readings began at 2:00 P.M. and concluded after 4:10 P.M.

Indoor dry bulb temperature measurements ranged from 68.9 °F to 74.6 °F. All indoor measurements for temperature were within the range of 68 to 75°F (at 50 percent relative humidity) as recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). The outdoor temperature measurements ranged from 68.3 to 70.1 °F'.

Relative HuMidity

The relative humidity indoors ranged from 46.0 percent to 58.8 percent. All indoor measurements for relative humidity were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. The outdoor relative humidity ranged from 58.0 to 60.1 percent.

Carbon Dioxide Concentration

Carbon dioxide concentrations indoors ranged from 506 ppm to 805 ppm. All of the measurements were below the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The maximum outdoor (background) CQ2 concentration was 491 ppm. Therefore, the maximum acceptable level of CO2 at this location was 1191 ppm (background level -1- 700 ppm). Levels above the recommended maximum do not indicate a health nsk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of CO? indoors is occupant respiration.

Carbon Monoxide Concentration

Carbon monoxide concentrations indoors were 2 ppm for all readings. These concentrations were below the NPAAQS/ASHRAE guideline of 9 ppm. The outdoor CO concentrations ranged from 1 ppm to 2 ppm.

Respirable Particulates (PM2,j)

Respirable particulate concentrations* indoors ranged between 11 pg/m^ to 28 pg/m^. None of the indoor or outdoor measurements for PM2 5 were above the NPAAQS of 65 pg/m^ 24- hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. Also none of the measurements were above the USEPA recommended concentration of 40 pg/m^ for st:nsitive individuals and children.

CITY_21MC100_002851735

NYC-WTC_000371835

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000371835Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →