NYC 9/11 Public Portal Document
Pace Analytical Services, Inc.
1700 Elm Street - Suite 200
Minneapolis, MN 55414
'^ace Analytical______ ___ Method 8290 Analysis Results
Tel: 612-607-1700
Fax: 612- 607-6444
Client - ATC
Client's Sample ID ATC-0419-M894-DX2
Lab Sample ID 103481396
Filename F20507A_12
Injected By BAL
Total Amount Extracted 1 m2 Matrix WIPE
% Moisture NA Dilution NA
Dry Weight Extracted NA Collected 04/19/2002
ICAL Date 05/04/2002 Received 04/23/2002
CCal Filename(s) F20507A_06 & F20507A_22 Extracted 04/30/2002
Method Blank ID BLANK-1606 Analyzed 05/07/2002 19:49
Native Cone EMPC LRL Internal ng's Percent
Isomers ng/m2 ng/m2 ng/m2 Standards Added Recovery
2,3,7,8-TCDF ND 0.00200 2,3.7,8-TCDF-13C 2.00 71
Total TCDF 0.053 0.00200 2,3,7.8-TCDD-13C 2.00 67
1,2,3,7,8-PeCDF-13C 2.00 57
2,3,7,8-TCDD ND 0.00200 2,3,4.7,8-PeCDF-13C 2.00 53
Total TCDD 0.079 0.00200 1,2,3.7,8-PeCDD-13C 2.00 53
1,2,3,4,7,8-HxCDF-13C 2.00 96
1.2,3,7,8-PeCDF ND 0.01000 1,2,3,6,7,8-HxCDF-13C 2.00 94
2,3,4,7.8-PeCDF ND 0.01000 2,3,4.6,7.8-HxCDF-13C 2.00 84
Total PeCDF ND 0.01000 1,2,3,7.8.9-HxCDF-13C 2.00 84
1.2,3,4,7,8-HxCDD-13C 2.00 88
1,2,3,7,8-PeCDD ND 0.01000 1.2,3,6,7,8-HxCDD-13C 2.00 82
Total PeCDD 0.022 0.01000 J 1,2,3,4,6.7.8-HpCDF-13C 2.00 ■ 87
1.2,3.4,7,8.9-HpCDF-13C 2.00 61
1,2,3,4,7,8-HxCDF ND 0.01000 1,2,3,4,6.7,8-HpCDD-13C 2.00 71
1,2,3,6.7,8-HxCDF ND 0.01000 OCDD-13C 4.00 62
2,3,4,6,7,8-HxCDF ND 0.01000
1.2,3,7.8,9-HxCDF ND 0.01000 1,2,3,4-TCDD-13C 2.00 NA
Total HxCDF ND 0.01000 1,2,3,7,8,9-HxCDD-13C 2.00 NA
1,2,3,4,7,8-HxCDD ND 0.01000 2,3.7.8-TCDD-37CI4 0.20 72
1,2,3,6.7,8-HxCDD ND 0.01000
1,2,3,7,8,9-HxCDD ND 0.01000
Total HxCDD 0.019 0.01000 J
1,2,3,4,6,7,8-HpCDF ND 0.01000 Total 2,3,7.8-TCDD
1,2,3,4,7,8,9-HpCDF ND 0.01000 Equivalence: 0.000097 ng/m2
Total HpCDF ND 0.01000 (Using ITE Factors)
1,2,3,4,6,7,8-HpCDD ND 0.01000
Total HpCDD ND 0.01000
OCDF ND 0.02000
OCDD 0.097 0.02000 J
LRL = Lower Reporting Limit '
Cone = Concentration (Totals include 2,3,7,8-substituted isomers) 1 = Interference '
EMPC = Estimated Maximum Possible Concentration E = PCDE Interference
A = Detection Limit based on signal-to-noise measurement S = Saturated signal
J = Concentration detected is below the calibration range ND = Not Detected
B = Less than 10 times higher than method blank level NA = Not Applicable
P = Recovery outside ot target range NC = Not Calculated
Nn = Value obtained from additional analysis * = See Discussion
Report No.... 02-1056604
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, Inc.
CITY_21MC1OO_OO28656OO
NYC-WTC_000370379
OCR can misread numbers and units. Confirm readings against the page image before using them.