IAQ report, P.S. 89M, May 2002

Machine-extracted title · confidence 45%

Indoor air quality measurements collected at P.S. 89M in May 2002.

NYC-WTC_000369182–000369185
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

104 East 25th St, 10th Floor New York, Now York 10010 wwwatc-onviro.com 212.3538280 Fax 212.353 8306 ASSOCIATES INC.

May 31,2002

Mr. Bernard P. Orlan Director, Environmental Health & Safely New York City Board of Education 28-1 I Queens Plaza North Long Island City, NY 11101-4008

Re: Indoor Air Quality Assessment P.S. 89M 201 Warren Street New York, New York 10282 ATC Project No. 15-19125-0297

Dear Mr. Orlan:

■ATC Associates Inc. (ATC) is pleased to provide this report of indoor air quality (lAQ) measurements collected on May 30, 2002, at the referenced school. The New York City Board of Education (BOE) requested these measurements to evaluate air quality in the school building.

SCOPE OF WORK

ATC conducted this evaluation to assess the basic parameters of temperature, relative humidity, carbtm dioxide (CO,) and carbon monoxide (CO).

ATC measured temperature, relative humidity, CO, and CO with a Q-Trak® Model 8551, manufactured by TSI, Inc.

ATC measured concentrations of respirable particulates (PM2,5) with a Dust-Trak - Aerosol Monitor Model 8520, manufactured by TSI, Inc.

ATC measured concentrations of Total Volatile Organic Compounds (TVOCs) using a RAE Systems, Inc. MiniRAE® photoionization detector (PID).

Mr. Kevin Fitzpatrick, Environmental Technician, of ATC’s New York City office, conducted the assessment.

ATC’s findings and conclusion.s are based on a visual inspection, real-time environmental measurements and conditions present in the school at the time of the assessment.

The assessment was performed consistent with generally accepted indoor air quality assessment practices. As with all such assessments, there were inherent limitations created by constraints of time, operational and work practice variability, variations in indoor air quality parameters and sampling and analytical accuracy. The results of the sampling represent conditions found on the dates of the survey and may not represent conditions found at other times. The information presented in this report should be used by the BOE as a guide to assess the need for further improvements in cunent indoor air quality control activities.

CITY_21MC100_002863263

NYC-WTC_000369182

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000369182Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →