NYC-WTC_000307895
Table of sampling methods for lead, PAHs, dioxin wipe samples; HUD/EPA methods listed.
9 shared non-person entities · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗Sampling instructions for lead, PAHs, dioxin, silica, mercury; wipe samples.
NYC-WTC_000369022
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Sampling and Analytical Procedures for Lead, PAHs, Dioxin, Fibrous Glass, Silica, and Mercury
1. Sampling for lead, PAHs, dioxin, fibrous glass, crystalline silica and mercury shall be performed by the wipe sampling technician. A completed chain of custody must accompany all samples. A unique sample number shall be assigned to each sample. A complete written description and/or diagram shall clearly identify each sampling location.
2. Post cleaning air samples for fibrous glass and silica shall be collected concurrently with the asbestos clearance air sampling procedures specified herein. Five samples for fibrous glass and one sample for silica shall be collected in each apartment.
3. Wipe samples shall be collected before and after cleaning for lead, mercury, dioxin, and PAHs.
Prior to the cleaning activities, three wipe samples shall be collected for each of these parameters in each apartment. The sampling locations shall be a wall, a bare floor, and a counter or tabletop.
After cleaning activities, three wipe samples shall be collected for each of these parameters in each apartment. The sampling locations shall be a wall, a bare floor, and a counter or tabletop; preferably at the same location as the pre-cleaning samples.
4. The required sampling and analytical procedures are specified in Table 1.
Table 1: Sampling and Analytical Methods Parameter Description Sampling Methodology Analytical Method Lead Wipe samples HUD Appendix 13.1 EPA Method SW-846-6010B PAHs Wipe samples ASTM D6661-01 ASTM-6661-01 EPA SW-846-8270C Dioxin Wipe samples ASTM 6661-01 ASTM 6661-01 EPA Method SW-846-8290 Fibrous Glass Air samples NIOSH 7400 NIOSH 7400, Counting Method “B” Crystalline Silica Air samples NIOSH 7500 NIOSH 7500 (XRD)_______ Mercury Wipe samples HUD Appendix 13.1 EPA Method SW-846 7471A
Asbestos Air Sample Collection and Analysis
1. All asbestos air samples collected during clean-up activities shall be analyzed via TEM. The method of analysis and sampling methodologies shall be in accordance with the applicable sections of Title 15, Chapter 1 of the Rules of the City of New York, and AHERA.
2. A turnaround time of 24 hours is required for all samples. Failure to do so will result in nonpayment.
3. Asbestos clearance air samples shall be analyzed in accordance with the NIOSH 7400 Method, and analyzed by PCM followed by TEM. The laboratory shall report a PCMe value of all fibers greater than 5 microns in length. Therefore, the lab shall report PCM, TEM and PCMe values for each sample. 3 of 5
CITY_21MC100_002862981
NYC-WTC_000369022
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000307895
Table of sampling methods for lead, PAHs, dioxin wipe samples; HUD/EPA methods listed.
9 shared non-person entities · similarity 0.968
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454690
Draft DEP scope of work for interior dust assessment and asbestos air monitoring at 114 Liberty Street.
7 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000424654
Draft scope of work for interior cleaning and air monitoring by licensed contractor at 114 Liberty Street.
7 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433356
Follow-up DEP scope of work for 114 Liberty Street asbestos/cleaning monitoring.
7 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000442883
Scope of work document for interior cleaning and asbestos monitoring at 114 Liberty Street.
7 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443993
Draft scope of work for asbestos cleaning and air monitoring at 114 Liberty Street.
7 shared non-person entities · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000429276
Draft chain-of-custody for 114 Liberty Street samples and lab analyses.
7 shared non-person entities · similarity 0.932
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000205550
Document outlining mandatory pre-bid meeting and scope for interior asbestos cleaning and air monitoring at 114 Liberty Street.
7 shared non-person entities · similarity 0.932
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000362544
Chain-of-custody form relating to dust sampling and asbestos abatement monitoring at 114 Liberty Street, Feb 2003.
7 shared non-person entities · similarity 0.932
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000232018
Laboratory report detailing sampling protocols for lead, PAHs, dioxin, and asbestos using wipe and air samples.
7 shared non-person entities · 1 shared topics · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000445979
Pre-bid/scope memo for asbestos air monitoring and on-site staff requirements.
8 shared non-person entities · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000163360
Technical specifications for air quality monitoring work at two Manhattan buildings.
8 shared non-person entities · similarity 0.931
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000279056
Pre-bid scope and coordination for asbestos abatement monitoring at 125 Cedar Street.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195796
Document outlining requirements for a pre-bid conference regarding asbestos abatement and air monitoring at a World Trade Center facility.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000435590
DEP memo outlining pre-bid meeting and asbestos monitoring for WTC renovation.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000446586
Chain-of-custody document detailing asbestos sample monitoring setup for 125 Cedar Street decontamination.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433215
DEP scope of work for 125 Cedar Street interior dust monitoring and abatement oversight.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433703
DEP/WTC project scope describing building debris, dust, and required asbestos air monitoring during cleaning.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000307895
Table of sampling methods for lead, PAHs, dioxin wipe samples; HUD/EPA methods listed.
Similar indexed content
NYC-WTC_000454690
Draft DEP scope of work for interior dust assessment and asbestos air monitoring at 114 Liberty Street.
Similar indexed content
NYC-WTC_000424654
Draft scope of work for interior cleaning and air monitoring by licensed contractor at 114 Liberty Street.
Similar indexed content
NYC-WTC_000433356
Follow-up DEP scope of work for 114 Liberty Street asbestos/cleaning monitoring.
Similar indexed content
NYC-WTC_000442883
Scope of work document for interior cleaning and asbestos monitoring at 114 Liberty Street.
Similar indexed content