Air sample results for WTC, Broadway Ave & 31st St, Queens, Oct 29, 2001.

NYC-WTC_000368139–000368154
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

PEDNEAULT ASSOCIATES, INC. ■'i NYCDEP-WTC j z z 631-467-8477 5-BORO SAMPLING I o METALS IN AIR H CD

|CALCULATION FOR OSHAID121/125G- METALS IN AIR VIA CASSETIE FILTER (37MM MILLIPORE) & MOBILE VACUUM PUMPS ;] s o o jA= Concentration of Analyte in sample solution (pg/ml) or (mg/L) I ■D c CT o' Ca5 O> jB=Concentration of Blank in sample solution (ng/ml) or (mg/L) ■D CO jSSV=> Sample Solution Volume ASSV" Analyte concentration x Sample Solution Volume AR= I O 3. 03 2 ■BSV=Blank Sample Volume BBSV=Blank concentration x Blank Sample Volume ■ AV o !rAB= Reagent Blank Concentration (pg/ml) or (mg/L) I o o c ! RABSV" Reagent Blank Sample Volume I 3 CD

5d= Dilution Factor (NONE) I Ino gravimetic factors tii-TWI’/FIELD BLANK I For the Trip Blank Analytical Value: IAV" Ait Volume Sampled i AR= (B X BSV) - (RAB X RABSV) IAR=Analytical Result Ia AV I I ARR^AnajjticalR^gdrmble^esnltin m{»/:m^ (rounded off to 3-sigma) I .TB (mg/Lj BS^" (ht) Tb X TBS^s BBSV \R-& AVLttere ■SsAR/AV; ANALYTE « ARRmg/m’ 0.076 100 7.6 0.062 100 6.2 1.4 30 0.0466667 Aluminum- Al 0.05 0?282 100 28.2 '0.097 100 9.7 18.5 30 0.6166667 Antimony-Sb 0.62 0:645 100 4.5 ■o.'o'29' 100 2.9 1,6 30 0.0533333 Arsenic-As 0.05 '6:603 100 0.3 'O.'O'O2' 100 0,2 0.1 30 0.0033333 Barium-Ba <0.01 0:601 100 0.1 '-d‘.O25 100 __ 2 0.1 30 0.0033333 Beryllium-Be <0..01 ....... ’-0:627 100 -2.1 100 0.4 30 0.0133333 Cadmium-Cd <0.01 '6:755 100 75.5 ''0?56 100 19.5 30 0.65 Calcium-Ca 0.65 ..... "-‘6:0'07 100 -0.7 '0.'005 100 -0.5 -0.2 30 -0.0066667 Chromium-Cr <0.01 0:606 100 0.6 "ojoT 100 . 1 -0.4 30 -0.0133333 Copper-Cu <0.01 0:i42 100 14.2 'oToss 100 5.8 8.4 30 0.28 Iron-Fe 0.28 o:6'o'2 100 0.2 -0.022 100 -2.2 2.4 30 0.08 Lead-Pb 0.08 '6:i"6'4 100 16.4 *0.1'38 100 13.8 2.6 30 0.0866667 Magnesium-Mg 0.09 o:6'3'i 100 3.1 '0.074 100 -4.3 30 -0.1433333 Manganese-Mn <0.01 1! o 100 100 I 30 Mercury-Hg <0.01 H 0?SBS 100 0.3 0.002 100 0.2 0.1 30 0.0033333 Nickel-NI <0.01 0.73 100 73 d“93T 100 ZHZ -20.1 30 -0.67 Potassium-K <0.01 I—i s ■*6:646 -’0:0’02 100 100 4.6 07026 -0.2 ""-d'.'0'04 100 100 ZS -0.4 2 0.2 30 0.0666667 Selenium-Se 30 0.0066667 Silver-Ag 0.07 o <0.01 o ■'2:61'7 100 261.7 100 28M -22.7 30 -0.7566667 Sodium-Na <0.01 o Io ■-'6:605 100 -0.5 100 -0.4 -0.1 30 -0.0033333 Thallium-TI <0.01 o ■'6:6’2‘3 100 2.3 0.023 100 2,3 0 30 0 Zinc-Zn <0.01 CO CT LAB ID #01100507-008

NYCDEP - TRIP/FIELD BLANK c-/.IFM Fil FR/NYnnFP-HA7MAT/mni 1 DORn? y|«! ‘

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000368154Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →