Lab report, World Trade Center-5, Queens air 10/01

Machine-extracted title · confidence 32%

Air/gas sample; aluminum concentration 0.04 mg/m3 (10/2001).

NYC-WTC_000391388–000391401
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

PEDNEAULT ASSOCIATES, INC. NYCDEP - VYTC z z ■< 631-467-8477 -I 5-BORO SAMPLING ■<

o o io [CALCULATION FOR OSHAID121/125G-- METAl^ IN AIR VIA C/KSSEtTE fiLTER (37MM MILUPORE) & MOBILE VACUUM PUMPS METALS IN AIR | co

I ■D o i A« Concentration of Analyte in sample solution (ng/ml) or (mg/L) c o CT o Ca3 jB"Concentration of Blank in sample solution (pg/ml) or (mg/L) ;i 1 I o' CD ■D Ca5 jSSV- Sample Solution Sample Scdiijtinn Volume AR= (A X SSV) - (B X BSV1 I■ o CO 3. CD I 03 ■ BSV"Blank Sample Volume BBSV"Blank concentration x Blank Sample Volume AV I O !rAB>* Reagent Blank Concentration (pg/ml) or (mg/L) I; o o c ! RABSV" Reagent Blank Sample Volume p I ■ 3 I CD •d- Dilution Factor (NONE) B I I Ino gravimetic factors For the Trip Blank Analytical Value: IAV= Air Volume Sampled AR= (B X BSV) - (RAB X RABSV) I iAR"Analytical Result iill AV I 5 ■ . IARR"Analytical Rcjjortable Result in m|^/m^ (rounded off to 3-sigma) I

A (mg/L) SSV (mL) A x gSV = ASSV B (mg/Q BSV(mL) B x Bgvi- BBgV ASSV-BSSV = AR AV Liters AR/AV ANALYTE ARR mg/m’ 0.082 100 8.2 0.07 100 7 1.2 30 0.04 Aluminum- Ai 0.04 ■■"6.2‘49" 100 24.9 0.049 100 4.9 20 30 0.6666667 Antimony-Sb 0.67 0.646" 100 4.6 ^0002 100 -0.2 ■ 4.8 ______ 30 0.16 Arsenic-As 0.16 '■"6.665" 100 0.5 0.004.. 100 0.4 ■ 0.1 30 0.0033333 Barium-Ba <0.01 ■”6.66?” 100 0.1 100 0 ■ 0.1 30 0.0033333 Beryllium-Be <0.01 ■”6.663" 100 0.3 o.ooT 100 o.-i ■ 0.2 ______ 30 0.0066667 Cadmium-Cd <0.01 ”‘"6J58"‘ 100 75.8 048 100 “ 73 ■ 27.8 30 0.9266667 Calcium-Ca 0.93 6.638 ’ 100 3.8 b’osT 100 3-1 ' 0.7 30 0.0233333 Chromium-Cr 0.02 ■”6.6i6"^ 100 1.6 0808 100 0.8 0.8 30 0.0266667 Copper-Cu 0.02 ■”6.3'96" 59.3 ■ 100 39.6 0393 100 -19.7 30 -0.6566667 Iron-Fe <0.01 ■”6.652" 100 5.2 0.067 100 ”67^ 4.5 30 0.15 Lead-Pb 0.15 ■■■6.695" 100 9.5 ■■■"0.087 100 8.7 0.8 30 0.0266667 Magnesium-Mg 0.03 100 44.6 ■■■■■q'Tss 100 13.8 ■ 30.8 30 1.0266667 Manganese-Mn 1.03 o wa 100 30 Mercury-Hg <0.01 0.001 100 0.1 0.006 100 -0.5 30 -0.0166667 Nickel-NI <0.01 H K ""o’s’es"' 100 56.3 ■"o'Yse 100 37.7 30 1.2566667 Potassium-K 1.26 I 0.687"" 100 8.7 100 1.5' 7.2 30

o I ""6.602"" ""4.539""' 100 100 0.2 453.9 0.001 ■■3.046 100 100 304.6 0.1 149.3 0.24 Selenium-Se 30 0.0033333 Silver-Ag 30 4.9766667 Sodium-Na 0.24 <0.01 4.98 o Io 100 5.3 ■"-676w 100 -0.5 5.8 30 0.1933333 Thallium-TI 0.19 o "”6.633"" 100 3.3 ■■b.O23 100 2.3 " 1 30 0.0333333 Zinc-Zn 0.03 CO CO PED ID #01100168-001 CT O •M; NYCDEP-BROADWAY & 31 ST QUEENS C7JFM FILES/NYCDEP-HAZMAT/mni mnWR xl<?

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000391389Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →