TEM air sample results, AMEX project, 2001

Machine-extracted title · confidence 28%

EnviroHealth TEM air results for AMEX project; sample date Sep 2001, received Sep 21, 2001.

NYC-WTC_000367487
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Enviroscience TEM AIR SAMPLE RESULTS ro If* Consultants, Inc. CLIENT: Tech Clean SAMPLE DATE: SqiteiDbet 20.2001 00 K' ISI PROJECT NAME: AMEX RECEIVED DATE. September 21.2001 o 2150 SwTfMrowN Avenue Ronkonkoma New York f 1 779 Final CleKance Ambient PHOhC <631)580-3191 Facsimil£; (631) 5803195 AREA: 22 Tiames. lOth Floor SAMPITR: L. Savarese f? WWW> MVIHOHG ALTH.ORG CUFNT #; 00-10233 CUSTODY # 8-04-09 ELAP# 1 teet cn NVtJXP #20053 IO (jJ

tn 00 <3 Sample » Samf^Location Start End Run Tune Flow Rate Vohune Filter Cone. Sensilivity Air Cone. W minutes Avg- Liters S/tnin2 S/cc _ S/cc O) cn

TEMPI 1015. lOlli Floor 1:12 5:31 259 10 2590 0.0 00019 <Scii3itivtty

TEMPI l010,_10thHopr , , 1:00 5:25 ,2M 10 2650 0.0, .. 0.0018 cScnsitivity TEM F3 1005, lOrh Floor 1:15 5:28 253 10 2530 0-0 _ 0.0019 <Scnsitivitv TEMF4 Center of 10th Floor 1:1S 3:50 155 JOL^ J550 0.0 0.0031 cScnsitivity

lEM F5 10th Floor Copy Area 1:10 3:55 15.5 10 J550 0.0 0,0031 <SensitiYity m 5

I n

I . , . S=Agbc*to} sttuctutes,cc=cublc cenMaoetets, nuumnitlinaeter Analyzed by: Dale Analyzed: < <=rlt-.5» than. Flow Rate'.nitlers per minute o H Samples were analyud using Philips 400r Tnasmistioo Blectroo Miaoscope. Asbestos ideolificatioB 1$ detemined by ibe nsotpbology, viaual Selected Area Electron Diffraction (SAED). and Elemeotal Analysis using an Energy Dfipenlve X-ray Analyzer (EDAX). Concentration tn the filter is calculated by taking Mie oundxr of aaheclos stmetures and dividing by (he area analyzed. Air concectraiJon is caicnisted by aniltiplying

I the effective filter area (EFA) by the filler concentcaiian and then dlvIdiBg by Ike voJunie of air collected in cubic ceotiaaeters (cc). The data pertaining to these calculatitns can be foand on (he AsbeaitK Count Sheet.

1 o o o o The ah- filter coacentratian relates only Io air fiber coateat When sample* are submitted by an outside agency for analysis. Enviroscience. can only guarantee the accuracy of the filter canoentrafioa. This repot may not be reproduced without the express permission of Eavbtiscieooe. TWs report can not he used » dahn endorseaaent of proihicts by NVLAP or any agency of Ibe U.S. OovernmenL I Ilie samples collected In ibe rupouse action area demmutraied a filter concentration of asbestos less than seventy structures per stpiare millimeter This response to KI CO on action is considnwt complete accorditig to EPA 40 CFR 763. o A result of zero rtnictmes per square tnilluneler is only applicable to Mie wca analyzed. Test results only reflect cooditiou at (he time samples were taken. o

NYC-WTC_000367487

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000367487Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →