NYC-WTC_000367265
TEM analysis results for AHERA at 385 [name], Building 500, Dec 2001.
2 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗TEM analysis results for AHERA air samples at 100 [name], Nov 29, 2001.
NYC-WTC_000367271
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document New rent New rone lOOiO wwwatc enuiro com 212 353 8280 Pax 212 353 8306 ASSOCIATES INC
November 29, 2001 ALC Environmental 115 W 3Ctn Street New York, NY 10001 Attn. Mr Joshua Sarett
Re- Report of TEM Analysis ?ear Mr. Sarstt
Following are tne results of transmission electron microscopy (TEM) analysis of air samples from our Group No 5990.
Client Gateway Plaza Mngt Corp Project Name Building 100 at Gateway Plaza - 345 South End Ave Location Sth Floor Samples received- 11/29/01
These results will confirm and document the data transmitted today to you. The analyses were performed in strict conformance witn the methodology of the AHERA Final Rule (CFR Occooer 30, 1983) for clearance of abatement sites. The results are as indicated on the attached document
Results reported as Struct/cc are a function of air vo-ume collected in the field and are, as such, not verifiable by t.nis laboratory This report may be reproduced only in ics entirety and not without prior permission of this laboratory If the post- abatement inside samples pass, Che response action may oe considered to have been completed The analyses were supervised oy Dr. Michael A. Gorycki, Director of Electron Microscopy.
We are pleased to note that our TEM lab has received full accreditation from NVLAP, as is currently required for recognized analysis of TEM air samples for AHERA projects, and also approval under the NY State DOH ELAP program. These analyses were performed by ATC d/b/a ATC Associates Inc. Please contact me regarding any questions relating to these materials.
Very truly yours,
Michael A. Gorycki, Ph.D. Director of Electron Microscopy
CITY_DEP_WORBY_CANNATA_SUBP_000004085
NYC-WTC_000367271
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000367265
TEM analysis results for AHERA at 385 [name], Building 500, Dec 2001.
2 shared non-person entities · 1 shared topics · similarity 0.981
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367277
Transmission electron microscopy report on air samples; AHERA methodology.
2 shared non-person entities · 1 shared topics · similarity 0.980
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409393
TEM analysis results for air samples from Building 600; AHERA clearance context.
2 shared non-person entities · 1 shared topics · similarity 0.979
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367381
TEM air-sample analysis results for AHERA clearance at building.
2 shared non-person entities · 1 shared topics · similarity 0.975
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367275
TEM analysis results of air samples from [name] Management site; AHERA conformance.
2 shared non-person entities · 1 shared topics · similarity 0.972
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367289
TEM analysis results for air samples from Building 300; AHERA method.
2 shared non-person entities · 1 shared topics · similarity 0.971
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367409
TEM asbestos analysis results documenting AHERA clearance data.
2 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367296
Transmission electron microscopy results for air samples at Building 100 clearance site.
3 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367273
TEM analysis report for air samples at Building 200, 355 [name] Ave, Nov 2001.
2 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367263
TEM analysis results and THM transmission context for Building 400, 375 [name] Ave.
2 shared non-person entities · 1 shared topics · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342681
TEM analysis results for Building 100 air samples, Oct 2001.
2 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000342670
TEM analysis of air samples from Building 400 at 375 [name] Ave, AHERA-compliant.
2 shared non-person entities · 1 shared topics · similarity 0.958
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000367265
TEM analysis results for AHERA at 385 [name], Building 500, Dec 2001.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367277
Transmission electron microscopy report on air samples; AHERA methodology.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000409393
TEM analysis results for air samples from Building 600; AHERA clearance context.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367381
TEM air-sample analysis results for AHERA clearance at building.
Similarity score 0.988 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121138
Air monitoring report for 345 South End Avenue buildings conducted in December 2001 showing TEM results.
Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367275
TEM analysis results of air samples from [name] Management site; AHERA conformance.
Similarity score 0.986 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000367265
TEM analysis results for AHERA at 385 [name], Building 500, Dec 2001.
Similar indexed content
NYC-WTC_000367277
Transmission electron microscopy report on air samples; AHERA methodology.
Similar indexed content
NYC-WTC_000409393
TEM analysis results for air samples from Building 600; AHERA clearance context.
Similar indexed content
NYC-WTC_000367381
TEM air-sample analysis results for AHERA clearance at building.
Similar indexed content
NYC-WTC_000367275
TEM analysis results of air samples from [name] Management site; AHERA conformance.
Similar indexed content