Scope of Work
2.1 Air Sampling Procedures
ALC's licensed technician collected air samples using the TEM Methodology
The an samples were collected usmg high volume an samplmg pumps. Once the pumps were m
place the air samplmg techmcian recorded the locanon, time, date, sample numbers, pump number,
flow rate, stan and stop times and his initials.
The air cassette was mdependent of the pump motor. This is to prevent the vibrations of the motor
from affecting the fibers m the cassette. A separate stand or tnpod was used to hold the cassette m
place. The cassette was angled 45 degrees downward from the horizontal stand. This is to insure
that no asbestos will drop mto the cassette while sampling.
Using a rotameter, we calibrated each pump to the required flow rate, notmg this rate on the
san^ile record. After calibratmg the pumps, the end cap from the cassette was removed; the pump
was turned on and run for the required amount of time.
The samplmg pumps were checked penodically to ensure they were still operatmg, the cassettes
were still in place, and no one has disturbed the equipment. If at any time the area bemg sampled
was suspected of havmg high fiber counts, the filter mside the cassettes were exammed for
“overloadmg”, or an excessive amount of fibers and/or debns on the filter.
When the pre-detemuned volume of air has been collected, the techmcian then calibrated the
samplmg pump again to determine the current flow rate This rate will often be different from the
flow rate measured at the begmnmg of the sampling period That difference is usually due to the
clogging of the filter, thereby adding mcreased resistance to the flow of air
Once the pre-determined volume of air has been reached, the time was recorded as well as on the
cassette Before the pump was turned off. the cassette was angled upward and the cap replaced
and the end plug The cassettes were placed in sealed contamers. labeled with an identifying code
and a sample log was kept The samples were then submitted to the laboratory to be analyzed for
asbestos content A cham of custody record was prepared and accompamed the samples to the
laboratorv
2.2 Asbestos Analysis and Methodology
Each air sample is cross-referenced by field designation and lab internal code to ensure proper
consistent handling through a chain of custody Sample preparation lakes place within a HEPA
Filter clean bench to avoid any possible contamination Air sampling was conducted at a level
approximating the breathing zone of persons anticipated to be present in the area during normal
operations Samples collected represent the typical airborne fiber concentration of the area
3. Findings and Conclusions
Forty (40) air samples were collected and analyzed via TEM Methodology. The results indicated that
the areas achieved the acceptance cntena below <70 structures per inm2 set by the above regulations
s
CITY_DEP_WORBY_CANNATA_SUBP_000004078
NYC-WTC_000367261