Scope of Work
2.1 Air Sampling Procedures
ALC's licensed technician collected air samples using the TEM Methodology
The air samples were collected usmg high volume air samplmg pumps Once the pumps were in place the air sampling techmcian recorded the location, time, date, sample numbers, pump number. flow rate, start and stop times and his imtials
The air cassette was independent of the pump motor This is to prevent the vibrations of the motor from affecting the fibers m the cassette A separate stand or tnpod was used to hold the cassette in place The cassette was angled 45 degrees downward from the horizontal stand This is to insure that no asbestos will drop into the cassette while samplmg
Using a rotameter, we calibrated each pump to the required flow rate, notmg this rate on the sample record After calibranng the pumps, the end cap from the cassette was removed, the pump was turned on and run for the required amount of time
The samplmg pumps were checked periodically to ensure they were still operatmg, the cassettes were still m place, and no one has disturbed the equipment. If at any time the area being sampled was suspected of havmg high fiber counts, the filter inside the cassettes were examined for “overloading”, or an excessive amount of fibers and/or debns on the filter
When the pre-determined volume of air has been collected, the technician then calibrated the samplmg pump agam to determme the current flow rate This rate will often be different from the flow rate measured at the beginmng of the samplmg penod. That difference is usually due to the cloggmg of the filter, thereby addmg mcreased resistance to the flow of air
Once the pre-determined volume of air has been reached, the time was recorded as well as on the cassette. Before the pump was turned off, the cassette was angled upward and the cap replaced and the end plug. The cassettes were placed m sealed contamers, labeled with an identifying code and a sample log was kept. The samples were then submitted to the laboratory to be analyzed for asbestos content. A cham of custody record was prepared and accompamed the samples to the laboratory.
2.2 Asbestos Analysis and Methodology
Each air sample is cross-referenced by field designation and lab mtemal code to ensure proper, consistent handling through a cham of custody. Sample preparation takes place within a HEPA Filter clean bench to avoid any possible contamination. Air samplmg was conducted at a level approximatmg the breathmg zone of persons anticipated to be present in the area durmg normal operations. Samples collected represent the typical aubome fiber concentration of the area.
3. Findings and Conclusions
Thirty six (36) air samples were collected and analyzed via TEM Methodology. The results indicated that the areas achieved the acceptance cnteria below <70 structures per mm2 set by the above regulations
CITY_21MC1OO_OO2861954
NYC-WTC_000210695
OCR can misread numbers and units. Confirm readings against the page image before using them.
Related records
Browse subjects →Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
Same-box records
8 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗5 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗6 shared non-person entities · 1 shared topics · similarity 0.960
machine-extracted · confidence unavailable · Check page ↗Filed elsewhere
NYC-WTC_000117668
Chain of custody documentation for bulk sampling and air monitoring at 385 South End Avenue Building 500.
8 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117536
Chain of custody documentation for bulk sampling and air monitoring at 345 South End Avenue Building 100.
8 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117757
Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.
8 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117723
Chain of custody documentation for bulk sampling and air monitoring at 365 South End Avenue Building 300.
8 shared non-person entities · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗6 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117479
Chain of custody documentation for bulk sampling and air monitoring at 375 South End Avenue Building 108.
8 shared non-person entities · 1 shared topics · similarity 0.965
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117493
Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.
8 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
4 shared non-person entities · similarity 0.959
machine-extracted · confidence unavailable · Check page ↗More like this page
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000121258
Air monitoring report for 345 South End Avenue buildings conducted in January 2002 showing TEM results.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121332
Air monitoring report for 345 South End Avenue buildings conducted in January 2002 showing TEM results.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121138
Air monitoring report for 345 South End Avenue buildings conducted in December 2001 showing TEM results.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121138
Air monitoring report for 345 South End Avenue buildings conducted in December 2001 showing TEM results.
Similarity score 0.992 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095454
Cover page for a monitoring report regarding environmental testing at 375 South End Avenue in 2001.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000121364
Chain of custody for air samples collected at 345 South End Avenue buildings in late January and early February 2002.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Others also read
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Chain of custody documentation for bulk sampling and air monitoring at 385 South End Avenue Building 500.
Similar indexed content
Chain of custody documentation for bulk sampling and air monitoring at 345 South End Avenue Building 100.
Similar indexed content
Similar indexed content
Cover page for a report detailing annual assessment, bulk sampling, and air monitoring activities at the specified address.
Similar indexed content
Chain of custody documentation for bulk sampling and air monitoring at 365 South End Avenue Building 300.
Similar indexed content