NYC-WTC_000367199
Metal scan/cert analysis of water from 21 South End Ave main, 2001.
5 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗Certificate of analysis for water from 21 South End Ave, lobby data, 2001.
NYC-WTC_000367201OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
10/16/2001 i4:19 7187298677 THE METRO GROUP PAGE 06/14
M SO-23 Twenf^Thim street Long Island City, NY 11101 TEL-(718) 729-7200 THE METRO CROUP, INC. S&ry/cing Wat&r Systems vt'/t/t Sffffironments/ Cere
FAX: (718) 7298077 CERTIFICATE OF ANALYSIS METAL SCAN ANALYSIS BROWN HARRIS STEVENS analysis NO.: 8371-2 NEW YORK, NY DATE: 10Z15Z01 SAMPLING DATE: 9/26/01
SOURCE OF SAMPLE - WATER FROM 21 SOUTH END AVE. - LOBBY M Tests, Chemical analysis for confonnanca with Safe Drinking Water Art? PAR your SAFE DRINKING WATER ACT RESULT MAX, contaminant LEVEL Chloride 14.1 250 mg/L Color 10.0 IS Units Conductivity 124 umhs/cm Fluoride 0 84 2.2 mg/L CorresiVTty (LS.I.) -258 Units NitrateN 0.27 10.0 , mg/L Odor 0 3 ' Units pH 8.9 e.5-8.S Units Sulfate 7.6 250 mg/L Total Alkalinity 21.8 mg/L Total Dissolve Solids 112 Turbidity <1.0 5.0 ntu Arsenio <3.0 50.0 ug/L Barium <0.20 2.0 mg/L Cadmium <5.0 5.0 Calcium 867 mg/L Chromium <0.01 1.0 mg/L Copper <0.04 1.3 mg/L Lead <1.0 15.0 Iron 0.04 .30 mgA. Magnesium 2.18 mg/L Manganese 0.02 0.30 Sodium 10.8 250. mg/L Total Hardness 30.6 mg/L Zino <0.02 5.0 mg/L CODES: MCL (Maximum Cairtaminant Level}, mg/L (milGgrams/lter - ppm),' iridiciates analyte exceeds EPA/SDWA proposed maximum contamination level.
COMMENTS: ALL PARAMETERS FALL WITHIN THE MAXIMUM CONT/KMINANT LEVELS STIPULATED FOR A SAFE DRINKING WATER. JD:gn /g<ik.l>irvish!adeh LABORATORY MANAGER
Responsible Ore Ctxd chemistry at Work
CITy_21MC100_002861841
NYC-WTC_000367201
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000367199
Metal scan/cert analysis of water from 21 South End Ave main, 2001.
5 shared non-person entities · 1 shared topics · similarity 0.984
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367019
Metal scan analysis report for water sample from apartment 25J, 380 Rector Place.
4 shared non-person entities · 1 shared topics · similarity 0.953
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367205
Certificate of analysis for metal scan; sampling date 10/5/01; results include chloride, color, conductivity, and fluoride.
3 shared non-person entities · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000230964
Cover letter summarizing asbestos test results from dust and air samples collected in September and October 2001 at a residential apartment.
5 shared non-person entities · similarity 0.911
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000282815
Water analysis report for Chase project, Broad Street, 9/2001.
4 shared non-person entities · similarity 0.899
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367203
Certificate of analysis for metal scan; sampling date 10/5/01, results include chloride, fluoride, color, and conductivity.
5 shared non-person entities · 1 shared topics · similarity 0.896
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363817
Laboratory report listing Cadmium to Manganese levels and references for drinking water standards.
5 shared non-person entities · similarity 0.896
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367198
Bacteriological water tests from sources at Metro Group site indicate good sanitary quality.
Similar document embedding; no shared entity or topic indexed. · similarity 0.895
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000282814
Water analysis report for Chase project, Broad Street, 9/2001.
5 shared non-person entities · similarity 0.894
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367204
Water sampling from lobby bathroom; bacteria count and coliforms results with absence of coliforms noted.
Similar document embedding; no shared entity or topic indexed. · similarity 0.893
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000367018
Certificate of analysis for water sample from apartment master bath/shower.
Similar document embedding; no shared entity or topic indexed. · similarity 0.890
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000120368
Summary of dust, air, and water test results for 21 South End Avenue dated November 2, 2001.
5 shared non-person entities · similarity 0.915
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Metal scan/cert analysis of water from 21 South End Ave main, 2001.
Similar indexed content
NYC-WTC_000367019
Metal scan analysis report for water sample from apartment 25J, 380 Rector Place.
Similar indexed content
Certificate of analysis for metal scan; sampling date 10/5/01; results include chloride, color, conductivity, and fluoride.
Similar indexed content
Summary of dust, air, and water test results for 21 South End Avenue dated November 2, 2001.
Similar indexed content
NYC-WTC_000230964
Cover letter summarizing asbestos test results from dust and air samples collected in September and October 2001 at a residential apartment.
Similar indexed content