NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Chain-of-custody: PCM air sampling, 2 [name] Ave, 2001

Machine-extracted title · confidence 39%

Chain-of-custody for PCM air sampling at 2 [name] Ave, NYC, Sept–Oct 2001.

NYC-WTC_000367185–000367186
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

02-15-2002 OS :17pm From-COOPER SQUARE f12l2G348920 T-521 P 004/010 F-rOl

Cooper Square Realty JLC Project #01*2104 September 25,2001 page 2 Air Sampling Analysis and Procedure

Introduction Air sampling is defined as the process of measuring the filter content of a known volume of air entrained on a filter membrane over a specified period or time. Each sample is cross-referenced by field designation and a JLC lab internal code to ensure proper, consistent handling through a chain of custody. Sample preparation takes place within an HiiPA filter clean bench to avoid any possible contamination.

Methodology Test procedures for these samples conform to the National Institute of Occupational Safety and Health (NIOSH) standards.

Air sampling was conducted at a level approximating the breathing zone of persons anticipated to be present in the area during normal operations. SamphiS collected should represent the area's typical airborne fiber concentration.

All samples were collected on fully exposed 25 millimeter, 0.8 micrometer (pm) cellulose ester membrane air sampling cassettes v/ith conductive cowl.

Analytical Procedures A section of the filter approximating twenty-five percent c-f the total filter was removed and placed on a pre-cleaned microscope slide and then exposed to approximately 250 microliter (pl) of acetone vapor A single 3.0 - 3,5 pl drop of triacetin was applied and a clean #1.5 cover slip was placed upon the filter. The prepared slide was then heated on slide heater until clarity allowed analysis to be conducted.

Analysis was accomplished utilizing a Phase Contrast Microscope in accordance with NIOSH 7400 method, counting rule "A"

Phase Contrast Microscopy JLC Environmental's laboratory uses an Olympus SH-P(' Phase Contrast Microscope, (PCM) equipped with a Walton-Beckett Graticule Samples weie analyzed by first dissolving the filter through a chemical process (described above) and then counting the fibers with PCM at 400x magnification Phase contrast increases the light contrast between the object and the background, thus enhancing the microscopist's ability to see fibers. Normally. 100 microscopic fields or 100 fibers are counted, whichever occurs first.

Analytical Results The "Summary of Analytical Results" represents the results of the analysis of the samples. The PCM limit of reliable quantification is less than 0 01 fiber Jcubic centimeter (f/ce) of air If final teste do not meet these requirements, the entire work site mu 4 be re-cleaned and re-tested.

CITY_21MC100_002861823

NYC-WTC_000367186

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000367186Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000390358

Chain-of-custody and results for PCM air samples at 80 [name], NY.

Similar indexed content

Compare copies and versions →