NYC 9/11 Public Portal Document
Attn: F. Burkhard Received: 11/1/01 8:00:00 AM
ATC Associates Inc
104 East 25th Street ATC Group#: 5802
New York NY 10010 Analysis Date: 11/1/01
Fax: (212) 353-8306 Phone: (212)353-8280
Project: Parc Plase
225 Rector Street
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area Non Asbestos Structures Sensitivity Concetration
Sample l^olume Analyzed Asb 5fl (S/cc) fS/mm^f (S/cc) Notes
22 - 1300 00 0.0674 0 None Detected 0 0 0 0044 <14.83 < 0.0044
5802 -19
2* - 1300 00 0.0674 0 None Detected 0 0 0.0044 <14.83 <0.0044
5802 -20
25 - 1300 00 0 0674 0 None Detected 0 0 0.0044 <14.83 <0.0044
5802 -21
26 - 1300 00 0 0674 0 None Detected 0 0 0 0044 <14.83 <0.0044
5802 -22
27 - 1300 00 0.0674 0 None Detected 0 0 0.0044 <14.83 <0.0044
5802 -23
28 - 1300.00 0.0674 0 None Delected 0 0 0.0044 <14 83 < 0.0044
5802 -24
29 - 1300 00 0 0674 0 None Detected 0 0 0.0044 <14 83 <0.0044
5802 -25
30 - 1300.00 0.0674 0 None Detected 0 0 0 0044 <14.83 <0 0044
5802 -26
ROMAN PEYSAKHOV MICHAEL A GORYCKI, Ph.D.
Analyzed by. Approved by-
Disclaimer The laboratoiy is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel This lab b only responsible
for data reported in structures/mm' This report may not be reproduced, except in full, without wntten approval by ATC Associates Inc. This report may not be used to claim
product endoisement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples reported above. Quality control data (including 9S%
. confidence limits and laboratoiy and analysis' accuracy and precision) is available upon request
Accredited for NVLAP PLMTEM #101187-0, NY State ElAP #10879
CITY_DEP_WORBY_CANNATA_SUBP_000002688