Asbestos TEM analysis, 225 Rector Place, Nov 2001

Machine-extracted title · confidence 18%

Asbestos TEM analysis with results for 225 Rector Place, Nov 2001.

NYC-WTC_000366697
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Attn: Mr. BenSallemi Received: 11/17/01 8:00:00 AM ATC Associates Inc 104 East 25th Street ATC Group#; 5907 New York NY 10010 Analysis Date: 11/19/01 Fax; (212) 353-8306 Phone: (212)353-8280 Project: 225 Rector Place 225 Rector Place

Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos ztrca Non 'Asbestos Structures Sensitivity Concentration Sample k'olume Analyzed Asb e.5f,-5 (S/cc) (S/cc) Notes 9 1300.00 0 0674 0 None Detected 0 0 0.0044 <14.83 <0.0044 5907 -9

10 - 1300 00 0,0674 0 None Detected 0 0 0.0044 < 14.83 <0.0044 5907 -10

11 1300 00 0 0674 0 None Detected 0 0 0.0044 < 14.83 <0.0044 5907 -Il

12 - 1300 00 0 0674 0 None Detected 0 0 0.0044 <14.83 < 0.0044 5907 -12

13 - 1300 00 0.0674 0 None Detected 0 0 0.0044 <14.83 <0.0044 5907 -13

14 - 1300.00 0 0674 0 None Detected 0 0 0 0044 < 14.83 <0.0044 5907 -14

15 - 1300.00 0.0674 0 None Detected 0 0 0.0044 <14.83 <0.0044 5907 -15

16 - 1300.00 0 0674 0 None Detected 0 0 0.0044 <14.83 <0.0044 5907 -16

■ 1300 00 0.0674 0 None Delected 0 0 0.0044 < 14.83 <0.0044 5907 -17

MICHAEL GORYCKI MICHAEL A. GORYCKI, Ph.D.

Analyzed by

Disdaimer The laboratory is not responsible for data reported in stnictureslcc, which is dependent on volume collected by non-laboratoiy personnel. Ths lab s only responsible for date reported in structures/mn? Ths report may not be reproduced, except in full, without written approval by ATC Assocates Inc. This report may not be used to claim product endorsement by NVLAP or any other agency of the U.S, Government Ths reports relates only to the samples reported above. Quality control data (rnduding 95% confidence limits and laboratory and analysis' accuracy and precision) is available upon request

Accredited for NVLAP PLMTTEM #101187-0, NY State ELAP #10879 %

CITY_DEP_WORBY_CANNATA_SUBP_000002633

NYC-WTC_000366697

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000366697Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000365150

Asbestos TEM analysis for Tribeca Towers project; AHERA method, 11/29/01.

Similar indexed content

Compare copies and versions →