NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Ambient Group memo, indoor environmental surveys, NY

Machine-extracted title · confidence 40%

Memo listing services for indoor environmental quality surveys and related programs.

NYC-WTC_000366042
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

/2oor. 24:27 FA.T 2129444618 AMBIENT GROUP 1^002

national HBADOnARTRnS ambient group inc. 55 WETTj^.. STKEBT Indoor environmental quality surveys Ilm FLOOR Water treatment consulting NEW YORK, NDV TURK JOOJS

©IS Asbestos e lead held sendees Regulatory compliance programs Air, water a soil analytical laboratories 7BU C2IJ) 0+4-46'5 EaK OU) 9+4-4618 WEs: wwjjumiNTCRoup.coji

December 27, 2001

Mr. Elliot Zuckerman Cushman &-Wakefield a/a/f Mercantile Exchange One North End Avenue New York, New York 10282

Re: One North End Avenue Ambient Project # 211338

Dear Mr. Zuckennan:

The following is a summary of the indoor environmental quality survey that Ambient Group, Inc. performed on December 18, 2001 at One North End Avenue. The survey included sampling for airborne metals (including silica scan), polynuclear aromatic hydrocarbons and airborne asbestos structures by TEM.

Four (4) air samples were collected from floors 3, 7, 11 and 15 and analyzed by transmission electron microscopy (TEM) for asbestos structures. The results of the analysis indicated that airborne asbestos levels at the time of testing were less than the analytical sensitivity of the instrument, which is well below the EPA standard of 70 structures/mm^ as well as other recommended industry guidelines and/or regulations.

Four (4) air samples were collected from floors 3, 7, 11 and 15 and analyzed for metals in air (including silica). All measured metals revealed levels well below their respective DSHA PELS and NIOSH RELs. Levels of cristobalite and quartz detected in the silica scan were also below the NIOSH REL of 0.05 mg/m^.

Four (4) air samples were collected from floors 3, 7, 11 and IS and analyzed for polynuclear aromaric hydrocarbons in air. Analysis of all four (4) samples collected revealed that the levels of the individual compounds were below the OSHA Permissible Eaqjosure Limits and NIOSH REL guidelines.

Please refer to the attached laboratory data sheets for further details. Should you have any questions regarding this information, please feel free to call me.

Sincerely, Signed for Ambient Group, Inc. by;

JL/nt AtcacbmenU

MXAbCr. FT. CHICAGO, n. corona, ca OLBN C0V14, tir 516 Sag-oqpg 860-0101 901; 171-47JV JU 517-5526 211338

12/27/01 THU 15:25 [TX/RX NO 8890]

CITY_21MC100_002860891

NYC-WTC_000366042

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000366042Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Ambient Group services proposal, Feb 2002

NYC-WTC_000210392

Fax cover sheet from Ambient Group dated February 12, 2002, offering environmental quality surveys and asbestos field services.

Similar indexed content

Compare copies and versions →