NYC 9/11 Public Portal Document
GCI ENVIRONMENTAL ADVISORY!NC.
655 Third Avenue New York, NY 10017 (212) 986-9460 Fax: (212)986-9464
September 28, 2001
Mr. Frank Vasta
Rockrose Development Corp.
309 East 45*'^ Street
New York, NY 10017
Re: 99 John Street, NYC - Apt. 604
Dear Mr. Vasta,
GCI Environmental Advisory, Inc. has collected ambient air samples within the
apartments and common areas of the above referenced building during September 20 -
26, 2001.
Air sampling was conducted utilizing 0.8 u, MCE sampling cassettes employing high
volume air sampling pumps during "normal" building activities.. A minimum of Nine
Hundred (900) liters of air was collected to provide a detection limit below 0.01 f/cc
(fibers per cubic centimeter). All samples were pre- and post-calibrated by means of
a precision rotometer that had been calibrated with a primary standard. Sampling
blanks were collected and submitted with each group of samples analyzed. Air sample
analysis was according to NIOSH Analytical Method 7400 with results reported as
fibers per cubic centimeter (f/cc). Laboratory Analysis performed by an ELAP approved
and NIOSH PAT proficient laboratory.
Laboratory analysis indicated airborne levels below the current recommended
"Clearance Air Criteria" of 0.01 fibers per cubic centimeter (f/cc) of air according to
Phase Contrast Microscopy (PCM).
Should you have any questions or need additional information, please contact me at
(212) 986-9460.
/mcerelv,
President
GCI ^vironmental Advisory, Inc.
JFG/gj
GCI ENVIRONMENTAL ADVISORY, INC. PROJECT 2001 N01-B4085.99.APT.PCIVI
CITY_21MC100_002842874