NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 29 pages

TEM TEM Analysis, Tribeca Towers 5771-62566

Machine-extracted title · confidence 57%

TEM analysis details for Tribeca Towers sample set 5771 series with diffraction and EDS data.

NYC-WTC_000365640–000365668
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

ATC Associates Inc. Approved N.Y. State ELAP #10879 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187 New York, NY 10010 Report Date: 10/2S/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Enercy-Dispersive X-RAY Spectroscopy iEDS) Method: AHERA Final Role, EPA Federal Register (40 CFR. Part 763), Vcl. 52, No. 210, October 30, 198^

Sample Identification Analysis Parameters

Project/Site: Tribeca Towers, 105 Duane St., NY, NY TEM Sample No.; 5771 625€6 Various Sites Dace Received: lQ/26/01 Grid Openings Analyzed:__ 6

Project Sample No.: 01 Average Grid Opening: 106.00 um

Air Volume .•lJ^0 litei^ Total Area Analyzed: 0.0674 mm2

Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity :14^8 s2mm2 Effective Area: 385 mm2 0.0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundies Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nqm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0 . 0000 0

Amphibole Asbestos 0 0 0 0 0.0 0 . 0000 0

Ambiguous 0 0 0 0 0 0 0.0 0 . 0000 0

Total asbestos (includes ambiguous structures) 0 0 0.0 0.0000 0 Non-Asbestos 0 C 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 0 0 0.0 0 . 0000 N/A

Totals (All Structures) 0 0 0. 0 0 . 0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by; Report Reviewed by.

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_002849326

NYC-WTC_000365640

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000365640Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000365613

TEM analysis details for Tribeca Towers, sample H-1 with diffraction and EDS data.

Similar indexed content

NYC-WTC_000365476

Asbestos TEM analysis results for Tribeca Towers sample 5761; 1300 L air volume.

Similar indexed content

NYC-WTC_000365560

TEM analysis results for Tribeca Towers, sample 5770 with opening and area details.

Similar indexed content

Compare copies and versions →