NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 43 pages

TEM Analysis, Tribeca Towers 5770

Machine-extracted title · confidence 58%

TEM analysis results for Tribeca Towers, sample 5770 with opening and area details.

NYC-WTC_000365560–000365602
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

ATC Associates Inc. Approved N.Y. State ELAP #10879 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187 New York, NY 10010 Report Date: 10/26/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM) wi Fiber Identification by Selected-Area Electron Diffracticn :S?a5L' and Energy-Dispersive X-RAY Spectroscopy iEDS; Method: AJIERA Final Rule, E?A Federal Register <40 CFR, Part 76_j», Vol. 52, No. 210, October 30, 1987

Sample IdentificacL Analysis Parameters

Project/Site: Related, Tribeca T.R., 105 Duane St.,. NY NY TEM Sami No.; 5749 52531 Various Sites Dace Received: lC_y26/2i Grid Openings Analysed:__ 6

Project Sample Nc.: 25 Average Grid Opening :

Air Volume -. 1300 liters Total Area Analyzed

Filter Type; MCE 25 mm diam., Pore Size: 0.45 um Anaiyticai Sensitiv. 14.3 s.^nm2 Effective Area: 385 mrn2 0.0044 s/cc

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION

Single Ma' To: Filter Air Fibers Bundles Clusters Struct Struct Zmm2 Struct/co nqm/m3

Chrysotile Asbestos 0 0 0 0.0 0.0000 0

Amphibole Asbestos c C 0 0.0 0 . 0000 0

Ambiguous 0 c 0 0 0 0.0 0 . 0000 0

Total asbestos (includes ambiguous struci es 0,0000 0 Non-Asbescos 0 0 0 C.0 0.0000 N/A No Identification 0.0 0.0000 N/A

Totals 1 Structures) 0.0 0 . 0000 N/A The estimated uncertainty of this analysis is 1 standard a

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_002849224

NYC-WTC_000365581

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000365581Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000365476

Asbestos TEM analysis results for Tribeca Towers sample 5761; 1300 L air volume.

Similar indexed content

NYC-WTC_000365640

TEM analysis details for Tribeca Towers sample set 5771 series with diffraction and EDS data.

Similar indexed content

NYC-WTC_000365613

TEM analysis details for Tribeca Towers, sample H-1 with diffraction and EDS data.

Similar indexed content

Compare copies and versions →