TEM Analysis, Tribeca Towers, 5761

Machine-extracted title · confidence 58%

Asbestos TEM analysis results for Tribeca Towers sample 5761; 1300 L air volume.

NYC-WTC_000365476–000365512
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

ATC Associates Inc. Approved N.Y. State ELAP #10879 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187 New York, NY 10010 Report Date: 10/25/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM; With Fiber Identification by Selected-Area Electron Diffraction <5AED: and Energy-Dispersive .Y-RAY Spectroscopy Method: AHERA Fi.hal Rule, ERA Federa_ Register (40 EFR, Part 763;, No. 210, October 3C, 1987

Sample IdentificaCLon Analysis Parameters

Project/Site: Related, Tribeca T.R., 105 Duane St., NY, NY TEM Sample No.: 5761 52207 Various Sites Date Received: 10/25/01 Grid Openings Analyzed;__ 6

Project Sample No.: 34 Average Grid Opening: 106.00 urn

Air Volume: 1300 liters Total Area Analyzed : C^0674[t^

Filter Type: MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity: 14.S s/mm2 Effective Area: 3S5mm2 0.0044 s/cc

FIBROUS PARTICULATES AN7VLYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Bundles Clusters Struct. Struct > = 5um Struct/mm2 Struct/cc nqm/m3

C.nrysotile Asbestos c 0 0 c 0 0 0.0 0 . 0000 0

Amphibole Asbestos 0 0 0 0 0 0 0.0 0.0030 0

Ambiguous 0 0 0 0 0 0 0.0 0 . 0000 0

Total asbestos (includes ambiguous structures] c O' 0.0 0 . 0000 0

Non-Asbestcs 0 0 0 c 0 0 0.0 0 . 0000 N/A No Identification 0 0 0 c 0 0.0 0 . 0000 N/A

Totals (All Structures) 0 0.0 0.oooo N/A

The estimated uncertainty of this analysis is 1 standard deviation

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Report Reviewed by:

Marek Peysakhov Michael A. Gorycki, Ph.D. Direccor of Electron Microscopy

CITY_21MC100_002849148

NYC-WTC_000365505

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000365505Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000365560

TEM analysis results for Tribeca Towers, sample 5770 with opening and area details.

Similar indexed content

NYC-WTC_000365640

TEM analysis details for Tribeca Towers sample set 5771 series with diffraction and EDS data.

Similar indexed content

NYC-WTC_000365613

TEM analysis details for Tribeca Towers, sample H-1 with diffraction and EDS data.

Similar indexed content

Compare copies and versions →