TEM Analysis, Tribeca Towers, 5761

Machine-extracted title · confidence 58%

Asbestos TEM analysis results for Tribeca Towers sample 5761; 1300 L air volume.

NYC-WTC_000365476–000365512
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Environmental, Inc. 104 East 25th Street New York, New York 10010

ATC Associates Inc. Approved N.Y. State ELAP #10879 104 East 25th Street ACCREDITED NVLAP Lab Code # 1187 New York, NY 10010 Report Date: 10/25/01

ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY iTEM'- With Fiber Identification by Selected-Area Electron Diffraction (SAED! and Energy-Dispersive X-RAY Spectroscopy (EDS': Method: AHERA Final Rule, EPA Federal Register (40 TFR, Part 753). Vol. 52, No. 210, October 30, 1987

Sample IdencifLcacion Analysis Paratnecers

Pro]ect/Site: Related, Tribeca T.R., 105 Duane St., NY, NY TEM Samole No.: 5751 Various Sides Date Received: 10/25/01 Grid Openings Analyzed:__ 6

Project Sample No.; 41 Average Grid Opening :

Air Volume :^^^001j^^ers Total Area Analyzed: 0 . C674 mm2

Filter Type; MCE 25 mm diam., Pore Size: 0.45 um Analytical Sensitivity :M.;8 sdTim2 Effective Area: 385 mm2 0 . Q044

FIBROUS PARTICULATES ANALYZED Number Observed CONCENTRATION Total Single Matrix Total. Struct. Filter Air Fibers Sundies Clusters Struct Struct > = 5um Struct/mm2 Struct/cc ngm/m3

Chrysotile Asbestos 0 0 0 0 0 0 0.0 0.0000 0

Ainphrboie Asbestos Q 0 0 0 0 0.0 0 . 0000 0

Ambiguous 0 0 0 0 0 0 0.0 0 . 0000 0

Total asbestos :includes ambiguous structures! O' . c O'. 0000 Non-Asbestos 0 0 0 0 0.0 0.0000 N/A No Identification 0 0 0 0 c 0 0.0 0.0000 N/A

Totals lAll Structures; 0 0.0 0.0000 N/A The estimated uncertainty of this analysis is 1 standard deviation.

Non-asbestos fiber i.d. (EDS/SAED): None detected Amphibole Asbestos Type: None detected

The Analysis was carried out in accordance with the approved TEM method. This laboratory is in compliance with the quality specified for the method.

Analyzed by: Reporz Reviewed by;

Marek Peysakhov Michael A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_002849155

NYC-WTC_000365512

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000365512Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000365560

TEM analysis results for Tribeca Towers, sample 5770 with opening and area details.

Similar indexed content

NYC-WTC_000365640

TEM analysis details for Tribeca Towers sample set 5771 series with diffraction and EDS data.

Similar indexed content

NYC-WTC_000365613

TEM analysis details for Tribeca Towers, sample H-1 with diffraction and EDS data.

Similar indexed content

Compare copies and versions →