S‘^bJob#: 202071471 I Page of 1 Client Name: GLOMAR CORP. Table I Summary of Bulk Asbestos Analysis Results 59 Maiden Lane, New York City (7th Floor) Wipes

SciLab Client HG Sample Heat Acid Insoluble Sample ■ # Sample# Area Weight Sensitive Soluble Non-Asbestos Asbestos by Asbestos by Location (gram) Organic % Inorganic % Inorganic % PLM/DS TEM 01 01 Chrysotile Present NA 7-1 Williams Side Of Bldg. Middle Window Sill 02 02 Chrysotile Present NA 7-2 Williams Side Of Bldg. 10th Window From John St. 03 03 NVA Chrysotile Present 7-3 John St. Side Of Bldg. Last Window Comer John Williams 04 04 Chrysotile Present NA 7-4 John St. Side Middle Window 05 05 Chrysotile Present NA 7-5 End Window Towards Broadway

O

I o m ■0

§ O 20 1 DO Analyzed by; lonathan M. Teda. Date Analyzed 7/7/02 Quantitative Analysis (Scmi/Full); Bulk Asbestos Analysis - PLM by ERA 6OO/M4-82-O2O per 40 CFR (NVLAP Lab#200546-0); TEM (Semi/Full) by EPA 600/R-93/116 (not covered by NVLAP Bulk accreditation); > or ELAP 198.1/198.4 for New Yorlj samples INYSDOH ELAP#I 1480); NAD = no asbestos detected during a quantitative analysis; NA = not analyzed; Trace = <1%; Quantitation for beginning weights of <0.1 grams should be considered as qualilative only; Qualitative Analysis: Asbestos analysis results of "Present" or "NVA = No Visible Asbestos" represents results for Qualitative PLM or TEM Analysis only (no accreditation z coverage available from any regulatory agency for qualitative analyses); AIHA Lab# 102843. Warning Note: PLM halation, only TEM will resolve fibers <0 25 micrometers in diameter. TEM bulk analysis is representative of the fine grained matrix material and may not be representative of non-uniformly > dispersed debris for^mieh PLM evalualfSn is recomm)lnded (i.e. soils and other heterogenous materials). 'co Reviewed By: /S----- c □0

o o o r\7 o CD

NYC-WTC_000363437

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363437Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →