EMSLNYCNOBCHTFIELDSOP 200.0 Revison 1 February, 2002 3.0 SAMPLE ANALYSIS

Sample Preparation Acceptance 1. More than 50% of-the grid must be eovered by the replica. 2. Grids must have at least 50% intact grid openings. 3. Grids must not have more than 10% opaque area due to incomplete filter dissolution. 4. Total Grid openings must have <50% overlapping of folded replica film 5. At least 20 grid openings with <5% holes and <5% opaque area due to incomplete filter dissolution. 6. Grid openings analyzed must not have rips or overlapping folds.

Bulk (Chatfield & NOB) 1. Remove the first sample grid from the box and insert it into the TEM. At a magnification of 300 to 500x, orient an intact grid opening on the middle of the screen. 2. Increase magnification to 3,000 or 19,000x taking care to remain in the chose grid opening. 3. Randomly scan the sample choosing fields with a moderate loading of debris. 4. Estimate the percent asbestos vs. the percent debris on each field. Ignore any fields that do not contain debris. Cover several areas of the filter in case of a non- hompgenequs sample. To better estimate the true percent, tilt the sample in order to visualize a three-dimensional picture as a two-dimensional image may be misleading causing false high asbestos percents. 5. Calculate the average asbestos concentration from all of the fields analyzed and record the estimated concenteration (for NYNOB) or the estimated range (for Chatfield analysis). 6. If a fibrous structure has been located, check its morphology against the morphologies for each asbestos type. If morphology is consistent with asbestiform fibers, proceed to EDX analysis. Obtain an EDX of the sample by following the procedures outlined in ENERGY— DISPERSIVE X-RAY ANALYSIS SOP and compare it to the spectra for the asbestos types. Record the information on the sample worksheet. If the chemistry is consistent with one of the asbestiform minerals, proceed to Diffraction analysis. 8. Obtain a diffraction pattern for the sample by following the procedures outlined in DIFFRACTION ANALYSIS SOP. Record diffraction information on the sample worksheet. 9. If the morphology, diffraction, and EDX information match that of an asbestos type, then record the structure as asbestos. 10. For asbestos structures, there is no need to note fiber, bundle, matrix, or cluster. 11. Working magnification is 3,000 and 10,000 to 19,000x. 12. Fiber criteria - Estimate range percent of asbestos 13. Sizing of fibers - Not recorded 14. Required EDX - The first five structures and every tenth there after 15. Required diffraction patterns

Controlled Copy Page 4 of 7

CITY_21MC100_002848036

NYC-WTC_000363433

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363433Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →