NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Lab client lease - LMB, WTC

Machine-extracted title · confidence 41%

Lease-related sampling data and dates for WTC property, May 2002.

NYC-WTC_000363275
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TESTWELL LABO RATORIES, INC.

lllL Environmental Laboratory 47 Hudson Street, Ossining, New York 10562 NYS ELM> » 11M2 NVIAP » 200083-0 AIHA # 100147

Transmission Electron Microscopy Results Client: Bovis Lend Lease - LMB 200 Park Avenue New York, New York Date Collected: 05/24/02 Date Rec'd (lab): 05/26/02 Sample Location: Millenium Hilton Hotel @ WTC (Various Floors) Analysis Date: 05/28/02 55 Church Street TEM Analyst: D. McCarl New York, New York Analytical Method: AHERA

Field Technician: T. Chhetry

Filter Type: MCE 0.45 micron vg.Grid Opening: 0.0121mm^ Volume Grid Lab Number Grid Area Countable Asb. Concentration Concentration Sample #; Sample Location; Coll. Openings 02TEM # (liters) Analyzed Analyzed Structures Stnictures/mm* Structures/cc

Inside Work Area 37 2445 1280.0 6 0.073 1 13.77 0.004 56th Floor Inside Work Area 38 2446 1280.0 6 0.073 1 13.77 0.004 56th Floor Inside Work Area 39 2447 1280.0 6 0.073 2 27.55 0.008 56th Floor Inside Work Area 40 2448 1280.0 6 0.073 1 13.77 0.004 56th Floor Inside Work Area 41 2449 1280.0 6 0.073 1 13.77 0.004 56th Floor Inside Work Area 42 2450 1280.0 6 0.073 N/A OVERLOAD OVERLOAD 49th Floor Inside Work Area 43 2451 1280.0 6 0.073 N/A OVERLOAD OVERLOAD 49th Floor Inside Work Area 44 2452 1280.0 6 0.073 N/A OVERLOAD OVERLOAD 49th Floor Inside Work Area 45 2453 1280.0 6 0.073 0 <13.77 <0.004 49th Floor Inside Work Area 46 2454 1280.0 6 0.073 0 <13.77 <0.004 49th Floor Inside Work Area 47 2455 1280.0 6 0.073 0 <13.77 <0.004 48th Floor Inside Work Area 48 2456 1280.0 6 0.073 0 <13.77 <0.004 48th Floor Structures/mm^ Stnjctures/cc 1 [Total Average Concentrations N/A N/A This report is the confidential property of our clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or any agency of the United Slates Government, The laboratory has no control over air sampling collection. This certificate of analysis/report shall not be reproduced in full, without the written approval of Testwell Laboratories, Inc.

Laboratory Diractor/Approved Signatory

41

■s

CITY_21MC100_002858470

NYC-WTC_000363275

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363275Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Lab report, hotel at WTC, Jun 2002

NYC-WTC_000363299

Laboratory results for Hotel at World Trade Center project; client lease-LMB, dates in June 2002.

Similar indexed content

Compare copies and versions →