Lab report, PCM air sample, Hilton @ WTC, 2002

Machine-extracted title · confidence 25%

PCM air sample results for Hilton at WTC; lab results indicate acceptability.

NYC-WTC_000363262
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TESTWELL LABORATORIES, INC. Environmental Laboratory NYSELA?# 11142

47 Hudson Street, Ossining, New York 10562 NWAP # 200083-0 AIHA # 100147

PCM AIR SAMPLE RESULTS Client; Bovis Lend Lease Date Collected; 05/28/02 Date Rec'd (lab): 05/29/02 Project #: MBO-025AB Analysis Date; 05/29/02 Analyst; 4, Sokol Sample Location Millenium Hilton @ WTC 55 Chruch Street Analytical Method: NIOSH 7400 New York, New York Various Floors Sample Condition Acceptable? YES Field Technician T. Chhetry

Sample Concentration Sample #: Sample Location: 02PCM # Volume Type f/cc

Outside Work Area Clean Room of 337 During 14590 1350 <0.0018 Remote Personal Decon Outside Work Area Remote Waste 338 During 14591 1350 0.0022 Decon Outside Work Area 46th Floor Inside 339 During 14592 1350 <0.0018 Airlock Outside Work Area 46th Floor 340 During 14593 1350 0.0024 . Freight Elevator Lobby Outside Work Area 45th Floor Inside 341 During 14594 1350 OVERLOAD Airlock. Outside Work Area 45th Floor 342 During 14595 1350 0.0029 Freight Elevator Lobby Outside Work Area 44th Roor Inside 343 During 14596 1350 0.0038 Airlock Outside Work Area 44th Roor 344 During 14597 1350 0.0035 Freight Elevator Lobby

345 Field Blank Blank 14598 0 N/A

346 Field Blank Blank 14599 0 N/A

• Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is calculated by using the higher value of either die actual concentration or the limit of quantification reported at P(0.05) indicating the 95% confidence level at 2 standard deviations. ** Sample information is provided by the client & presented as stated. Laboratory QC data available upon request ***’ The laboratory has no control over air sampling collection. Reports are the confidential property of our clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government This certificate of analysis/report shall not be reproduced except in full, without the written approval of Testwell Laboratories, Inc.

Deborah McCari - Laboratory Director

Page 1 of 1 5

CITY_21MC1OO_OO2858455

NYC-WTC_000363262

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363262Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →