PCM air sample results, NYS ELAP, 2002

Machine-extracted title · confidence 40%

Air sample results for PCM analyzed by NYS ELAP, collected 05/23/02.

NYC-WTC_000363254
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TESTWELL LABORATORIES, INC. Environmental Laboratory NYScLAP » 11142

47 Hudson Street, Ossining, New York 10562 NVL4P t 20083-0 AIHA 1 100147

PCM AIR SAMPLE RESULTS Client: Bovis Lend Lease Date Collected: 05/23/02 Date Rec’d (lab): 05/24/02 Project #: MBO-025AB Analysis Date: 05/24/02 Analyst: D. McCaii Sample Location Millenium Hilton @ WTC 55 Chruch Street Analytical Method: NIOSH 7400 New York, New York Various Floors Sample Condition Acceptable? YES Field Technician T. Chhetry

Sample Concentration Sample #: Sample Location: 02PCM # Volume Type f/cc

Outside Work Area 45th Floor Inside 279 During 14247 1200 0.0082 Airlock Outside Work Area 45th Floor 280 During 14248 1200 0.0053 Freight Elevator Lobby Outside Work Area 6th Floor MER 281 During 14249 1200 0.0084 Inside Airlock Outside Work Area 6th Floor MER 282 During 14250 1200 0.0106 Freight Elevator Lobby Outside Work Area Clean Room of 283 During 14251 1300 <0.0021 Remote Personal Decon Outside Work Area Remote Waste 284 During 14252 1300 0.0021 Decon Outside Work Area 56th Floor Inside 285 During 14253 1300 0.0030 Airlock Outside Work Area 56th Floor 286 During 14254 1300 0.0028 Freight Elevator Lobby Outside Work Area 49th Floor Inside 287 During 14255 1300 0.0026 Airlock Outside Work Area 49th Floor 288 During 14256 1300 <0.0021 Freight Elevator Lobby Outside Work Area 48th Floor inside 289 During 14257 1300 0.0034 Airlock Outside Work Area 48th Floor 290 During 14258 1300 0.0028 Freight Elevator Lobby ' Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 me’hod. The report value is calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95% confidence level at 2 standard deviations. ** Sample information is provided by the client & presented as stated. Laboratory QC data available upon request. **** The laboratory has no control over air sampling collection. Reports are the confidential property of our clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be reproduced except in full, without the written approval of Testwell Laboratories, Inc.

Debcrsh McCarl - Laboratory Cirector

Page 1 of 1

CITY_21MC100_002858445

NYC-WTC_000363254

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363254Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →