PCM air sample results, NYS ELAP, 2002

Machine-extracted title · confidence 40%

Air sample results for PCM analyzed by NYS ELAP, collected 05/22/02.

NYC-WTC_000363248
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TESTWELL LABORATORIES, INC. Environmental Laboratory NYS ELAP # 11142

47 Hudson Street, Ossining, New York 10562 rrvLAP » 200083-0 AIHA # 100147

PCM AIR SAMPLE RESULTS Client: Bovis Lend Lease Date Collected: 05/22/02 Date Rec'd (lab): 05/23/02 Project #: MBO-025AB Analysis Date: 05/23/02 Analyst: D. McCar/ Sample Location Millenium Hilton @ WTC 55 Chruch Street Analytical Method: NIOSH 7400 New York, New York Various Floors Sample Condition Acceptable? YES Field Technician T. Chhetry

Sample Concentration Sample #: Sample Location: 02PCM # Volume Type f/cc

Outside Work Area Clean Room of 252 During 14049 1300 <0.0021 Remote Personal Decon Outside Work Area Remote Waste 253 During 14050 1300 <0.0021 Decon Outside Work Area 56th Floor Inside 254 During 14051 1300 0.0034 Airlock Outside Work Area 56th Floor 255 During 14052 1300 0.0060 Freight Elevator Lobby Outside Work Area 49th Floor Inside 256 During 14053 1300 0.0038 Airlock Outside Work Area 49th Floor 257 During 14054 1300 0.0025 Freight Elevator Lobby Outside Work Area 48th Floor Inside 258 During 14055 1300 0,0070 Airlock Outside Work Area 48th Floor 259 During 14056 1300 0,0057 Freight Elevator Lobby Outside Work Area 47th Floor Inside 260 During 14057 1300 0,0040 Airlock Outside Work Area 47th Floor 261 During 14058 1300 0.0041 Freight Elevator Lobby Outside Work Area 6th Floor MER 262 During 14059 1300 0,0079 Inside Airlock Outside Work Area 6th Floor MER 263 During 14060 1300 0,0106 Freight Elevator Lobby * Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95% confidence level at 2 standard deviations. ’* Sample information is provided by the client & presented as stated. **• Laboratory QC data available upon request. ***• The laboratory has no control over air sampling collection. Reports are the confidential property of our clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be reproduced except in full, without the written approval of Testwell Laboratories, Inc.

Deborah McCah - Laboratory Director

Page 1 of 1

sew

CITY_21MC1OO_OO2858439

NYC-WTC_000363248

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363248Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →