TESTWELL LABORATORIES, INC. Environmental Laboratory NYS EUP # 11142

47 Hudson Street, Ossining, New York 10562 tMJiP » 200083-0 AIHA } 100147

' PCM AIR SAMPLE RESULTS Client: Bovis Lend Lease Date Collected: 05/21/02 Date Rec'd (lab): 05/22/02 Project #: MBO-025AB Analysis Date: 05/22/02 Analyst: 4. Sokol Sample Location Millenium Hilton @ WTC 55 Chruch Street Analytical Method: NIOSH 7400 New York, New York Various Floors Sample Condition Acceptable? YES Field Technician T, Chhetry

Sample Concentration Sample #: Sample Location: 02PCM # Volume Type f/cc

Outside Work Area 6th Floor MER 221 During 14000 1190 0.0056 Inside Airlock Outside Work Area 6th Floor MER 222 During 14001 1190 0.0058 Freight Elevator Lobby Outside Work Area Clean Room of 223 During 14002 1300 0.0021 Remote Personal Decon Outside Work Area Remote Waste 224 During 14003 1300 0.0023 Decon Outside Work Area 56th Floor Inside 225 During 14004 1300 0.0034 Airlock Outside Work Area 56th Floor 226 During 14005 1300 0.0028 Freight Elevator Lobby Outside Work Area 50th Floor Inside 227 During 14006 1300 0.0034 Airlock Outside Work Area 50th Floor 228 During 14007 1300 0.0040 Freight Elevator Lobby Outside Work Area 49th Floor Inside 229 During 14008 1300 0.0023 Airlock Outside Work Area 49th Floor 230 During 14009 1300 <0.0021 Freight Elevator Lobby Outside Work Area 48th Floor Inside 231 During 14010 1300 0.0026 Airlock Outside Work Area 48th Floor 232 During 14011 1300 0.0028 Freight Elevator Lobby * Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95% confidence level at 2 standard deviations. ** Sample information is provided by the client & presented as stated. "‘ Laboratory QC data available upon request The laboratory has no control over air sampling collection. Reports are the confidential property of our clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government This certificate of analysis/report shall not be reproduced except in full, without the written approval of Testwell Laboratories, Inc.

Deborah McCart • Laboratory Director

Page 1 of 1

CITY_21MC1OO_OO2858433

NYC-WTC_000363242

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363242Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →