NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

PCM air sample results, NYC site, 2002

Machine-extracted title · confidence 41%

Laboratory results for PCM air sample collected 05/21/02 at WTC-area site.

NYC-WTC_000363241
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TESTWELL LABORATORIES, INC. Environmental Laboratory NYSELAP# 11142

47 Hudson Street, Ossining, New York 10562 tJVLAP » 200083-0 AIHA # 100147

PCM AIR SAMPLE RESULTS Client: Bovis Lend Lease Date Collected: 05/21/02 Date Rec'd (lab): 05/22/02 Project#: MBO-025AB Analysis Date: 05/22/02 Analyst: A. Soka/ Sample Location Millenium Hilton @ WTC 55 Chruch Street Analytical Method: NIOSH 7400 New York, New York Various Floors Sample Condition Acceptable? YES Field Technician T. Chhetry

Sample Concentration Sample #: Sample Location: 02PCM # Volume Type f/cc

Outside Work Area Clean Room of 209 During 13988 1200 <0.0023 Personal Decon Outside Work Area Remote Waste 210 During 13989 1200 <0.0023 Decon Outside Work Area 56th Floor Inside 211 During 13990 1200 0.0043 Airlock Outside Work Area 56th Floor 212 During 13991 1200 <0.0023 Freight Elevator Lobby Outside Work Area 50th Floor Inside 213 During 13992 1200 0.0033 Airlock Outside Work Area 50th Floor 214 During 13993 1200 0.0027 Freight Elevator Lobby Outside Work Area 49th Floor Inside 215 During 13994 1200 <0.0023 Airlock Outside Work Area 49th Floor 216 During 13995 1200 0.0033 Freight Elevator Lobby Outside Work Area 48th Floor Inside 217 During 13996 1200 0.0031 Airlock Outside Work Area 48th Floor 218 During 13997 1200 0.0025 Freight Elevator Lobby Outside Work Area 47th Floor Inside 219 During 13998 1200 <0.0023 Airlock Outside Work Area 47th Floor 220 During 13999 1200 0.0025 Freight Elevator Lobby * Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95% confidence level at 2 standard deviations. ** Sample information is provided by the client & presented as stated. *** Laboratory QC data available upon request. **** The laboratory has no control over air sampling collection. Reports are the confidential property of our clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be reproduced except in full, without the written approval of Testwell Laboratories. Inc.

Deborah McCarl - Laboratory Director

Page 1 of 1

CITY_21MC100_002858432

NYC-WTC_000363241

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363241Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →