PCM air sample results, NYC site, 2002

Machine-extracted title · confidence 43%

Laboratory results for PCM air sample collected 05/17/02 at WTC-area site.

NYC-WTC_000363230–000363235
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TESTWELL LABORATORIES, INC.

Tit Environmental Laboratory 47 Hudson Street, Ossining, New York 10562 NYS ELAP # 11142

» 200083-0 «HA » lOOlt?

PCM AIR SAMPLE RESULTS Client: Bovis Lend Lease Date Collected: 05/17/02 Date Rec'd (lab): 05/20/02 Project #: MBO-025AB Analysis Date: 05/20/02 Analyst: D. McCar/ Sample Location Millenium Hilton @ WTC 55 Chruch Street Analytical Method: NIOSH 7400 New York, New York Various Floors Sample Condition Acceptable? YES Field Technician T. Chhetry

Sample Concentration Sample #: Sample Location: 02PCM # Volume Type f/cc

Outside Work Area Clean Room of 153 Personal Decon During 13515 1200 I 0.0029

Outside Work Area Remote Waste 154 During 13516 1200 <0.0023 Decon Outside Work Area 56th Fleer Inside 155 During 13517 1200 0,0027 Airlock Outside Work Area 56th Floor 156 During 13518 1200 0.0031 Freight Elevator Lobby Outside Work Area 53rd Floor Inside 157 During 13519 1200 0.0049 Airlock Outside Work Area 53rd Poor 158 During 13520 1200 0.0061 . Freight Elevator Lobby Outside Work Area 52nd Floor Inside 159 During 13521 1200 0.0059 Airlock Outside Work Area 52nd Floor 160 During 13522 1200 0.0090 Freight Elevator Lobby Outside Work Area 51st Floor Inside 161 During 13523 1200 0.0080 ' Airlock ' Outside Work Area 51st Floor 162 During 13524 1200 OVERLOAD Freight Elevator Lobby Outside Work Area 50th Floor Inside 163 During 13525 1200 <0.0023 Airlock Outside Work Area 50th Floor 164 During 13526 1200 0.0045 Freight Elevator Lobby • Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95% confidence level at 2 standard deviations. ** Sample information is provided by the client & presented as stated. Laboratory QC data available upon request. **** The laboratory has no control over air sampling collection. Reports are the confidential property of our clients. This certificate of analysis/report shail not be used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAtP) or any agency of the United States Government. This certificate of analysis/report shall not be reproduced except in full, without the written approval of Testweil Laboratories, Inc.

Deborsh McCari - Labcratory Director

Page 1 of 1

CITY_21MC1OO_OO2858421

NYC-WTC_000363230

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363230Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →