NYC 9/11 Public Portal Document
TESTWELL LABORATORIES, INC.
Environmental Laboratory NYSIUP » 11142
47 Hudson Street, Ossining, New York 10562 NVIAP s 200083-0
AIHA S 1CX)147
PCM AIR SAMPLE RESULTS
Client; Bovis Lend Lease Date Collected; 05/15/02
Date Rac'd (lab): 05/16/02
Project #; MBO-025AB Analysis Date: 05/16/02
Analyst; L. Chiaverini
Sample Location Millenium Hilton @ V/TC
55 Chruch Street Analytical NIOSH 7400
New York, New York
Various Floors Sample Condition Acceptable? YES
Field Technician T. Chhetry
Sample Concentration
Sample #; Sample Location; 02PCM # Volume
Type f/cc
Outside Work Area Clean Room of
90 During 12809 1200 0.0041
Personal Decon
91 Outside Work Area Waste Decon During 12810 1200 <0.0023
Outside Work Area 56th Floor irsde
92 During 12811 1200 0.0033
Airlock
Outside Work Area 56th Root
93 During 12812 1200 0.0065
Freight Elevator Lobby
Outside Work Area 55th Floor Inside
94 During 12813 1200 0.0029
Airlock
Outside Work Area 55th Root
95 During 12814 1200 <0.0023
Freight Elevator Lobby
Outside Work Area 54th Floor Inside
96 During 12815 1200 0.0045
Airlock
Outside Work Area 54th Roor
97 During 12816 1200 0.0025
Freight Elevator Lobby
Outside Work Area 53rd Floor Inside
98 During 12817 1200 <0.0023
Airlock
Outside Work Area 53rd Roor
99 During 12818 1200 0.0037
Freight Elevator Lobby
Outside Work Area 52nd Floor In.s:de
100 During 12819 1200 0.0033
Airlock
Outside Work Area 52nd Roor
101 During 12820 1200 <0.0023
Freight Elevatory Lobby
* Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report
value is calculated by using the higher value of either the actual concentration or the limit of quanbfication reported at
P(0.05) indicating the 95% confidence level at 2 standard deviations. ** Sample information is provided by the client &
presented as stated. ’** Laboratory QC data available upon request. **** The laboratory has no control over air
sampling collection. Reports are the confidential property of our clients. This certificate of analysis/repcrt shall not be
used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or
any agency of the United States Government. This ce.hificate of analysis/report shall not be reproduced except in full.
without the written approval of Testweil Laboratories, Inc.
Deborah McCari - Laboratory Director