NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Air sample chain of custody, project II, 2002

Machine-extracted title · confidence 38%

Chain of custody form for air sample from project II on 05/10/02 at WTC site.

NYC-WTC_000363211–000363213
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

TESTWELL LABORATORIES, INC. Environmental Laboratory NYS # 11M2

47 Hudson Street, Ossining, New York 10562 NVIA? » ;CX)O83<I AIHA J :CO147

PCM AIR SAMPLE RESULTS Client: Bovis Lend Lease Date Collected: 05/10/02 Date Rec'd (lab): 05/13/02 Project #: MBO-025AB Analysis Date: 05/13/02 Analyst: D. Agrest Sample Location Millenium Hilton @ WTC 55 Chruch Street Analytical NIOSH 7400 New York, New York Various Floors Sample Condition Acceptable? YES Field Technician T. Chhetry

Sample Concentration Sample #: Sample Location: 02PCM # Volume Type f/cc

Outside Work Area Clean Room of 25 During 12266 1200 0.0025 Personal Decon

26 Outside Work Area Waste Decon During 12267 1200 0.0035

Outside Work Area 56th Floor Inside 27 During 12268 1200 0.0037 Airlock Outside Work Area 56th Floor 28 During 12269 1200 0.0029 Elevator Lobby Outside Work Area 55th Floor Inside 29 During 12270 . 1200 0.0043 Airlock Outside Work Area 55th Floor 30 During 12271 1200 0.0023 Elevator Lobby Outside Work Area 54th Floor Inside 31 During 12272 1200 0.0033 Airlock Outside Work Area 54th Foor 32 During 12273 1200 0.0031 Elevator Lobby Outside Work Area Staircase 33 During 12274 1200 <0.0023 Landing to 53rd Floor Outside Work Area Outside Bldg, 34 During 12275 1200 0.0027 Rector St. side Entrance

35 Field Blank Blank 12276 0 <0.0023

36 Field Blank Blank 12277 0 <0.0023

* Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95% confidence level at 2 standard deviations. " Sample information is provided by the client & presented as stated. Laboratory QC data available upon request. •*** The laboratory has no control over air sampling collection. Reports are the confidential property of our clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be reproduced except in tull, without the written approval of Testwell Laboratories. Inc.

Deborah McCaii - Laboratory Director

Page 1 of 1

CITY_21MC100_002858397

NYC-WTC_000363212

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363212Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →