NYC 9/11 Public Portal Document

data. Overall, it appears that there may be a decreasing trend in the average number of cleaning events required to meet the clearance criteria based upon the degree of pre-cleaning contamination.

Residential Units that are More Heavily Contaminated (Lower Sam of Ranks) Required More Cleaning Events to Achieve the Clearance Criteria UnU Obsen>ah!e Cleaning Times Sumef Numeric Mid-point E^ual Dust Cleaned Ranks Grouping (irouping Grouping iwii significant 3A,3A,3B 3 1 13 5A miflitnat 3B.3B 2.7 27 3C significant IA,IA,3B 3 iOili .3D iiOllll significant significant 1A,1A 2A,2A 2 2 iliiiii ■iili Illi 4C significant lA 23 1.6 minimal 1 2A minimal 1B,1B 26 13 5D significant 3B I 34 1.3 15 3B minimal 34 3A minimal iiMil liiSi 35 1,7 4A minimal 00 2 45 iiiiiB It should be noted that there were two units in which the test was changed for the third cleaning event. Unit 3C was cleaned twice using Test I A. Test 3B was used for the tliird cleaning to achieve the health-based benchmarks. Unit 5C was cleaned twice using Test 3A. Test 3B was used for the third cleaning to achieve the health-based benchmarks. It is unclear if the change in the method, the additional cleaning event, or a combination of the two, was responsible for meeting the health-based benchmark

^^Using the rankings presented in Table 10.0, a semi-quantitative evaluation was made to determine if there was a difference in the number of cleaning events needed to meet the clearance criteria based on the measured concentrations of pre-cleaning contamination. The average number of cleaning events required to meet the clearance criteria was calculated using several different groupings of the sum of ranks. The first set of calculations used numeric breakpoints of 10-19, 20-29, 30-39, and >40. This grouping indicates a decreasing trend in the average number of cleaning events required. The second set of groupings used the mid-point 23.5. This grouping also indicates a decreasing trend in the average number of cleaning events required. The third grouping divided the data into an equal number of units. Although this grouping suggests a decreasing trend for most of the groupings, the decreased trend did not continue for the last set of data. Overall, it appears that there may be a decreasing trend in the average number of cleaning events required to meet the clearance criteria based upon the degree of pre-cleaning contamination. 112

CITY_21MC100_011063482

NYC-WTC_000363174

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000363174Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →