Lab report: WTC debris cleaning scope, July 2002

Machine-extracted title · confidence 36%

Laboratory text outlining compliance with EPA/OSHA/NYSDOL regulations for cleaning and sampling related to WTC debris.

NYC-WTC_000362992–000363003
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

1. Before beginning aggressive air sampling, forced air equipment (such as a 1 horsepower electric leaf blower) shall be used to direct exhaust air against walls, ceilings, floors and other surfaces. When directing the exhaust, caution shall be taken to minimize disturbance and potential damage to furnishings and personal belongings. ii. For modified aggressive air sampling forced air equipment shall not be employed. iii. All other procedures are identical for aggressive kjnoi aggressive air sampling. b. One 20-inch fan shall be installed per 10.000 < feeto :e and run at low speed. The fan shall operate continuously throt tout samj lallnotbe off until sampling is completed. c. For studio apartments 3 samples shall be collecte< L For l-bedror»m above 5 samples shall be collected. Samj lipment shall be ] m living areas and away from obstructions. The sari :tte must be placed on a tripod and not taped to existing surfaces. d. Common spaces will be sampled without the ui nd air devices (fans, leaf blowers etc). For small spaces, less thMfc^O square®® samples will be collected. For large spaces greater than 160 square f iet and le han 25,000 square feet 5 samples will be collected. For spaces greate r than 25,' square feet, 1 sample will be collected for each 5,000 square feet. Sai ipling equipment shall be placed away fi'om obstructions. The sampling cassette nusl be placed on a tripod directed downward at a 45 degree angle and not tape. to existing surfaces. e. Air samples shall be collected in accordance Hth the procedures specified in NIOSH 7400 Method for PCM and 7402 for TE^ . Air sampling cassettes need to be J monitored to enstire pumps are not >ing by monitoring flow rates. The minimum sample volume resquired is 3600 ii f. Wipe samples wi te collected a t 10 percent of the residences where sampling only has been request up to a maximum of 50 units, as instructed by EPA. This sampling will coi .st of the collection of one wipe sample each for dioxin, total ^ercury (a separate wipe sample is required for each parameter). Metals i 1 mercury wipe samples will be collected in accordance with procedin specified in HUD Appendix 13.1. Dioxin wipe samples will be collected accordance with the procedures specified in ASTMD 6661-01. 5* The cont ;tor shall document all the necessary information regarding sampling activities, fill out all field logs, data sheets, and chain-of-custody forms. The contractor shall use F2L for all sample and chain-of-custody documentation. Samples lift must be labeled and accompanied with completed chain-of-custody forms before ■■iiiiiB shipping to the designated laboratory. The label must include the EPA Project 11 Tracking Number. Samples will be packed, sealed and shipped to EPA Contract Laboratory for analysis. h. All information must be maintained using the secure EPA website (url, user name and password to be provided by EPA). Dates for monitoring and/or cleaning shall be provided to EPA electronically in an EPA approved format within 24 hours. Information on sampling activities (date, sample ID) shall be provided to EPA, via the

CITY_21MC100_003754680

NYC-WTC_000362996

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000362996Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000140306 · Box DEP Box 05

Procedures for obtaining work authorization, monitoring residential and HVAC cleaning, and reporting hazardous conditions to EPA.

Similar indexed content

NYC-WTC_000332061

Draft scope of work for WTC dust cleaning and related regulatory alignment.

Similar indexed content

Compare copies and versions →