NYC-WTC_000362887
Detailed risk tables and PCM-equivalent fiber metrics for asbestos exposure.
23 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Table of cancer risks vs asbestos air concentration; PCM-equivalent fibers definitions.
NYC-WTC_000362848–000362861OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
used it in past, but refused to use it for the rest of NYC. Memorandum addressed to Affected Parties and Responsible Officials from Cate Jenkins, Hazardous Waste Identification Division, OSW, EPA. Posted at www.NYenviroLAW.org.
The New York Environmental Law and Justice Project, as well as the New York City Department of Environmental Protection and the US EPA Region 2 tested dust from the roof and in an open elevator shaft of an apartment at 150 Franklin St. in April, 2002. Testing by PLM showed no asbestos. But when the exact same samples were retested using transmission electron microscopy (TEM), the dust had asbestos over 1%, and in one case at a level of 5%. Franklin St. is about 2 blocks north of the Hudson St. apartment building.
14. Pending rele ase of the information from the client, at this time, I cannot cite the source of this information.
15. Kominsky, J . R., et al. (1993) Evaluation <3f Three Cleaning Methods for Removing Asbestos from Carpet: Determination of Airborne Asbestos Concentrations Associated with Each Method, US EPyk Risk Reduction Engineering Laboratory, Cincinnati, OH 45268, EPA Publication No. EPA/600/SR-93/155, Posted at www.epa.gov/ncepihom/nepishom/
This study was for real-world asbestos contaminated carpet: A study was conducted to compare the effectiveness of three cleaning methods for removal of asbestos from contaminated carpet and to determine the airborne asbestos concentrattons associated with each. Baseline measurements before cleaning showed an average concentration of 1.6 billion asbestos structures per square foot (s/fE) of carpet. The effectiveness of dry vacuuming using cleaners with and without a high-efficiency particulate air filter was compared with that of wet cleaning with a hot-water extraction cleaner. The wet cleaning method reduced the level of asbestos contamination in the carpet by approximately 60%. whereas neither dry cleaning method had any notable effect on the asbestos level. The type of cleaner used had little effect on the difference between the airborne asbestos concentration before and during cleaning.
Kominsky, J. R., et al. (1991) Evaluation of Two Cleaning Methods for Removal of Asbestos Fibers from Carptet, US EPA Risk Reduction Imgineering Laboratory, Cincinnati, OH 45268, EPA Publication No. EPA/600/S2-90/053, posted at www.epa.gov/ncepihom/nepishom/
This study was for artificially asbestos contaminated carpet The effectiveness of dry-vacuuming and wet-cleaning for the removal of asbestos fibers from carpet was examined, and the potential for fiber reentrainment during carpet cleaning activities was evaluated. Routine carpet cleaning operations were simulated by using high-efficiency particulate ait (HEPA) filtered dry vacuum cleaners and HEPA- filtered hot-water extraction cleaners on carpet artificially contaminated with asbestos fibers. Overall, wet-cleaning with a hot water extraction cleaner reduced the level of asbestos contamination in the carfiet by approximately 70%. There was no significant change in carpet asbestos concentration after dry-vacuuming. The level of asbestos contamination had no significant effect on the difference between the asbestos
- 30-
CITY_21MC100_002847486
NYC-WTC_000362852
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000362887
Detailed risk tables and PCM-equivalent fiber metrics for asbestos exposure.
23 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302679
EPA memo detailing ultrasonication carpet test for asbestos in carpets; cost considerations.
23 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433480
EPA memo on carpet testing method for asbestos and related benchmarks.
23 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433176
EPA memorandum describing ultrasonication test method for asbestos in carpets.
23 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000433551
EPA memo detailing ultrasonication carpet testing method and cost implications.
23 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452613
EPA memorandum describing ultrasonication carpet/asbestos testing method.
23 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448447
Duplicate memo describing ultrasonication method for carpet dust; safety benchmarks.
23 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000418123
EPA memo describing ultrasonication method for asbestos in carpets and fabrics.
23 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000430642
EPA memo on ultrasonication carpet testing for asbestos reservoirs and findings.
23 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453034
EPA memo describing ultrasonication method for asbestos in carpets.
23 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140083
Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
23 shared non-person entities · 1 shared topics · similarity 0.992
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275438
EPA memorandum describing ultrasonication carpet dust test method for asbestos.
23 shared non-person entities · 1 shared topics · similarity 0.991
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000362887
Detailed risk tables and PCM-equivalent fiber metrics for asbestos exposure.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000275438
EPA memorandum describing ultrasonication carpet dust test method for asbestos.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140083
Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140040
Technical memorandum from EPA discussing ultrasonication testing for asbestos in carpets and HEPA vacuuming effectiveness.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000302679
EPA memo detailing ultrasonication carpet test for asbestos in carpets; cost considerations.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000140138
EPA memorandum addressing World Trade Center asbestos contamination status and agency efforts to provide information on the situation.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000362887
Detailed risk tables and PCM-equivalent fiber metrics for asbestos exposure.
Similar indexed content
NYC-WTC_000140083
Forwarded EPA memorandum dated June 9, 2002, concerning the Asbestos Reservoir and carpet testing methods.
Similar indexed content
NYC-WTC_000302679
EPA memo detailing ultrasonication carpet test for asbestos in carpets; cost considerations.
Similar indexed content
NYC-WTC_000433480
EPA memo on carpet testing method for asbestos and related benchmarks.
Similar indexed content
NYC-WTC_000433176
EPA memorandum describing ultrasonication test method for asbestos in carpets.
Similar indexed content