Asbestos air sampling results, NYC response, 9/26/01

Machine-extracted title · confidence 42%

Asbestos air sampling results for [name] area on 9/26/01; data visualization page.

NYC-WTC_000362824
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z ■< Z ■<

o o co g NYC Response o I Asbestos Air Sampling Results for Freshkill Landfill “0 o c o Sampling Date and Time: 09/26/01 0800 to 1800 CT o Ca3 o' o> PCM by NIOSH 7400 TEM by NIOSH 7402 TEIWl (AHERA) "0 ro o oo Sampling Sample f/mm^ f/cc AF/NAF Adjusted Structures (#) S/mm^ S~f/cc ro Sampling 4^ CD Date Sample No. Location Volume Matrix TEM f/cc <5m >5p 0 o 9/26/01 00751 #1 709 Air <7.0 <0 004 0/0 <0 004 0 0 <8 00 <0 0043 o c 9/26/01 00752 #2 651 Air <7.0 <0 004 0/8 <0 004 0 0 <8 00 <0 0047 3 648 Air <7.0 <0 004 0/3 <0 004 0 0 <8 00 <0 0048 CD 9/26/01 00753 #3 9/26/01 00754 #A 648 Air <7.0 <0 004 0/1 <0.004 0 0 <8 00 <0 0048 9/26/01 00755 #5 643 Air <7 0 <0 004 0/3 <0 004 0 0 <8 00 <0 0048 9/26/01 00756 #6 645 Air <7 0 <0 004 0/3 <0 004 0 0 <8.00 <0 0048 9/26/01 00757 #7 642 Air <7 0 <0 004 0/4 <0 004 0 0 <8.00 <0 0048 9/26/01 00758 #8 641 Air <7 0 <0 004 0/12 <0 004 0 0 <8 00 <0 0048 9/26/01 00759 #9A 626 Air 8 92 0 005 0/7 <0.004 2 1 24 0 0148 9/26/01 00760 #9B 627 Air 7 64 0 005 0/8 <0 004 0 0 <8 00 <0 0049 9/26/01 00761 10 637 Air 10 19 0 006 0/6 <0 004 0 0 <8 00 <0 0048 coc# 04008 NS Not sampled AF/ANF Asbestos fibers/Non asbestos fibers Sample volume is below recommended limit of the method ‘Structure (S) Roughly equivalent to Fiber (F) NA not analyzed due to overloading of particulates

NIOSH 7400: Fiber Analysis of Air samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94 NIOSH 7402: Asbestos Analysis of Air samples by Transmission Electron Microscopy Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA) Standard criteria: EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM). 70 S/mm’, volume 1200 L, for 25 mm filter (TEM)

ERT 09/28/01 2 00 PM

o H K I to

o o I o o on co FK-09-26-01A

CO

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000362824Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Lab report, NYC DEP

NYC-WTC_000368917

Unreadable lab report entry; no specifics

Similar indexed content

Compare copies and versions →