NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Analytical results review, 114 Liberty Street, Apr 2003

Machine-extracted title · confidence 32%

EPA review of air and wipe sample data for the 114 Liberty Street site under COPC criteria.

NYC-WTC_000362781–000362783
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Su m m a rv oftheAnalvticalResultsfortlieCh c m i ca 1 s of Potential Concern

USEPA’s review of the analytical data for samples collected from 114 Liberty Street indicate that the areas sampled meet the numeric criteria established in the workplan (Table 1). The values chosen were established in the draft “World Trade Center Indoor Air Assessment: Selecting Contaminants of Potential Concern and Setting Health-Based Benchmarks” report (i.e., COPC document). The COPC document was created by a committee with representation from federal, state, and city government and was designed to establish numeric criteria to be used in addressing potential contamination from dust and combustion by-products associated w'ith the World Trade Center collapse and fire. This document is currently undergoing peer-review. The data which was evaluated consisted of air or wipe samples for six chemicals, asbestos, polycyclic aromatic hydrocarbons (PAHs), dioxin, lead, fibrous glass, and crystalline silica.

Table 1: Clearance Criteria i:sed for. 14 Libert)' Street. Parameter Clearance Level Note Asbestos in air - PCMe 0.0009 s/cc Primary clearance level Lead in settled dust _______<25 pg/tf Primary clearance level Dioxin in settled dust rig/m^ Primary clearance level PAHs in settled dust _______ <300 pgW Primary clearance level _Fitrou£glas£m^ir_______________ <0.01 f/cc Secondary clearance level Crystalline silica in air 1 Secondary clearance level

Each area that was cleaned and sampled met the primary’ clearance levels identified in the work plan for. asbestos, pdyaydic aromatic hydrocarbons (PAHs), dioxin, and lead. The secondary clearance level for fibrous glass has also been met in the areas that were cleaned and tested. The secondary' clearance level for crystalline silica was met in 64% of the areas tested. The remaining areas were similar to background values observed from a USEPA background study. This is discussed in detail below. Since all of the primary clearance values have been met, the build-'ng can be released back to the owner.

There is one item that needs to be identified in relation to releasing the building to the owner, the area that contains the pizza shop. N^’CDEP staff has indicated that the area of the building which contains the pizza shop contains asbestcs-contairnng material (ACM). The ACM was considered to be in poor condition and the KS'CDEP has indicated that an asbestos abate will need to be undenaken in this area. Therefore, this space within the building is not considered to have met the primary clearance value for asbestos.

Bslcw is 2 summer}’ of the analytical results for each chemical.

Asbestos - Eighty-eight air samples were collected before and/or during cleaning events. Four samples exceeded 0.0009 s/cc and four samples could not be analyzed due to the filters being overloaded with particulate matter. The before/during cleaning samples were not used to evaluate if additional cleaning was needed.

Seven ty'-one air samples were collected after first-cleaning event. Ten samples exceeded 0.0009 s/cc and eight samples could not be analyzed due to the filters being overloaded with particulate matter. Based on these results, there were five areas that required additionak-cleaning-afid-sampling for asbestos. These areas were the 5*, 8*. 9^ and 10* floors.

Twenty-five air samples were collected from the 5% 7”', g”’, S"*, and 10'*' floors after the second-cleaning event. All samples were below the detection limit of 0.0004 s/cc and below the numeric criterion of

CITY_DEP_WORBY_CANNATA_SUBP_000018841

NYC-WTC_000362781

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000362781Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →