c 130 Liberty Street <x Bulk Heavy Metals Results Occupied Areas surveyed on September 28, 2001 IM c Air Plenums and Ducts surveyed January 16 to 19, 2002 c K Elevators surveyed January 21 and 22, 2002

Range of Results (ppm) Floor# Area Notes Cadmium Chromium Copper Lead Nickel Zinc Occupied area 5.94-6.13 85.15-93.22 135.15-166.74 63.37-101.09 15-17 1114-1173 IM I- 17 Return air plenum K CC Supply air ducts Occupied area a Ifi Return air plenum <2.93 -19.2 58.8 -199 336 -1530 87.1 -702 24-61 519 - 3200 OC Supply air ducts Occupied area 4.71 - 6.56 62-64 102-124 34-48 7.06 - 9.26 773 - 976 15 Return air plenum Supply air ducts Occupied area 14 Return air plenum Supply air ducts I I—

Occupied area 6.04 - 6.61 84-90 136-145 48-61 10.5-11.3 1043-1047 tr s 12 Return air plenum 6.67 - 8.63 77 -109 146- 1220 193 - 306 27-37 1190-43900 Supply air ducts <r Occupied area 5.92 - 6.28 109-142 126-148 39-66 16.6-22 c 900-953 c 11 Return air plenum Supply air ducts Occupied area 5.08-5.74 95-149 103-168 37-72 12.6-24 789-1008 o 10 Return air plenum Supply air ducts I o Occupied area 5.8 - 9. 08 124-144 165-218 32.9-103 16.4-23 856-1598 m 9 Return air plenum Supply air ducts o Occupied area 12.5-44 53-56 197-200 170-172 9.21 -14.0 1149-1245 B Return air plenum 6.44 -18.3 78 -158 225-756 173-455 29-57 1350-2620 Supply air ducts 'o Occupied area 7.93 - 14.8 61-87 132-183 9.01 -137 10.8-11.0 984-1184 > 7 Return air plenum 5.27-10.3 74-153 189-706 160-340 23-54 1150-3580 z z Supply air ducts

I cc c 5 Occupied area Return air plenum Supply air fans 4.69 - 5.81 5.43 - 49 2.77-41 55-71 64-127 54-192 77 -171 150-399 113-686 38 - 233 101 - 279 165-2750 8.71-11.3 19.5-35 16.1-48 1162-3113 1640-9640 2270-16600 |g c N ro C

o o o CD

tn

NYC-WTC_000362446

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000362446Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000182143

Summary of survey results for metals in floors, ducts, and elevators at 130 Liberty Street conducted between September 2001 and January 2002.

Similar indexed content

Compare copies and versions →