ATC metals, respirable dust and organics; 11/25/01

Machine-extracted title · confidence 32%

Metals, dust, quartz, and toluene results with exposure percent of TLV/PEL.

NYC-WTC_000362287
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Liberty Mutual / ATC Measurement Data

Weekly Sutnmaty

#of #of Highest Highest OSHA ACGIH Highest Result Job with Highest #ofNQs %NQ Comments Week of: Agent Class Samples Analyses Analyte Result PEL TLV %ofOEL Exposure

11/25/01 Total Dust/Metals 17 340 Cadmium 2.8uoAn3 5 ug'm3 lOug/mS 56% Of PEL Torch Cutter 198 58% 11/25.^1 Resp, DusVSilca 13 39 Quartz 0.018 mgmiS 0.1 me^3* 0.05 mg/md 36% of TLV Spotter 27 69% 11/26/01 Aromatic* 7 28 Toluene 0-0038 ppm 200 ppm 50 ppm 0.0076% of TLV Torch Cutter 26 93% 11/26/01 Aldehyde* 3 21 Formaldehyde 0.010 ppm 0.75 ppm 0.3 ppm (Caiing) 1.3% of PEL Backhoe Operator 15 71% 11/25A)1 PAHs 6 96 Total PAHs e.SugAnS 2OOuo/m3 2COuo/m3 3.4% of PEL Qreppief Operator 75 78% 11/25/01 Asbetto* 24 24 Fibers 0.033 f/cc 0.1 f/cc 0.1 f/cc 33% of PEL Spotter 17% 11/25«1 Acids 8 36 Hydrofluoric Acid 0.01 ppm 3ppm 3 ppm (CalHng) 0.33% of TLV Orappler Operator 59 164% 11/25/01 Ozone 2 2 N/A AI“TooLowtoQuantrf/ 2 100% 11/2S/D1 Carbon Monoxide (TWA) 26 26 Carbon Monoxide 33 ppm 50 ppm 25 ppm 132% of TLV (abPrav(atod Flagman 15 58% 1 peak over NIOSH Ceilng of 200 aampla * 2 hrs, 9 mln) ppm (Gmpptor Operator) Tolate: 104 612

12/1/01 Total DueVMetals 10 202 Arsenic 1 ug/m3 10ug/m3 10ufl/rn3 10% Of PEL Torch Cutter 122 60% 12/1/01 Resp. Dust/SIBca 8 24 Respirable Dust O.34mo/m3 SmtfmS 3mg/m3 11% Of TLV Equipment Operator 19 79% 12/1/01 Aromatic* 12 48 Benzene 0.0032 ppm 1ppm 0.5 ppm 0.64% of TLV Equipment Operator 31 65% 12/1/01 Aldehydes 8 42 Formaldehyde 0.017 ppm 0,75 ppm 0.3 ppm (CaiVng) 2.3% of PEL Equipment Operator 29 69% 12/1/01 PAHs 8 96 Total PAHs 17u9^m3 200ug/m3 200ug/m3 8.5% of PEL Torch Cutter 52 54% 12/1/01 Asbestos 26 26 Fibers 0.048 0.1 f/cc 0.1 f/cc 48% of PEL Spotter 5 19% 12/1/01 Adds 6 36 SuKuricAcid 0.059 m(Km3 1 mg/m3 1 mg/mS 5.9% of PEL Orappler Operator 31 68% 12/1/01 Ozone 8 8 N/A Art'TooLowtoQuentiiy’ 8 100% 12/1/01 Carbon Monoxide (TWA) 18 18 Carbon Monoxide 5ppm SO ppm 25 ppm 20% of TLV Torch Cuttar 14 78%

12/1/01 Hydrogen Sulfide 8 8 Hydrogen Sutftde 16 ppm 20 ppm (CdlSng) to ppm 160% of TLV (Area Sample) SW Comer, near south bridge 5 63% 12/1/01 Diesel Fume 11 11 Inorganie Carbon 0.075 mg/m3 3.5mQ/m3 3.B mg/m3 2 .2% of PEL Torch Cutter 9% Totals: Toe

Nole»:

The PEL for quartz Is determlneclby the formula PEL = 10 mgrrnS I (% quartz +2). For dusts ahh high quartz content mis aorta out to bo a quartz concentration of approximately 0.1 mgfms.

"OEL" ’ "occupational exposure Imit'. A generic term encompassing PELS, TLVs and other workplace exposure Imlts,

"NQ"»"not quantffiabte" Substance vas ms not present In sufficient quantity In the sample to report a firm value for the concentration. Al quantficatlon levels for the sampling methods used are reel below occupational exposure ImHs.

The area samples for hydrogen sulfide were taken near suspected sources and reere not representative of worker exposure. O

s Q o o I o o Oh on co

cn O',

NYC-WTC_000362287

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000362287Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →