NYC 9/11 Public Portal Document
Air Monitoring in Lower Manhattan Page 1 of 3
The City of New York
Department of Environmental Protection
V.tV'5. IS Air, Noise and Hazardous Materials
a' '
'Qc • •
Air Monitoring in Lower Manhattan
DEP monitored the ambient outdoor air for asbestos following the World Trade
Center (WTC) disaster. This effort augmented ambient air asbestos sampling
performed by the EPA and other state and city agencies. There is currently no
iiiiOsii 4 ■ ' '
outdoor ambient standard for asbestos. The US and NYC standard for asbestos in
community and residential buildings is 0.01 fibers/cubic centimeter (f/cc) in
indoor air. An indoor area which has had asbestos detected and then removed must
show that air samples are at or below the 0.01 f/cc standard before the indoor area
can be re-occupied. Although the ambient outdoor air was monitored, DEP used
the indoor air standard as a way to characterize the levels of asbestos in the air.
Since the measurement protocol used, phase contrast microscopy (PCM), counts
fibers, DEP also conducted an additional analysis for all samples that were above
0.01 f/cc. This measurement protocol is called transmission electron microscopy
(TEM) and counts the number of asbestos fibers in the sample. EPA reported their
data in TEMs, and provides a good explanation of the interpretation of the
standard that uses this methodology on their website.
... ' ■ , ,
EPA has also recently published the results of two studies related to the WTC
disaster; The Toxicological Effects ofFine Particulate Matter Derivedfrom the
Destruction of the World Trade Center, and The Exposure and Human Health
Evaluation ofAirborne Pollution from the World Trade Center Disaster. To read
both reports, please dick here.
Results indicate that, as expected, asbestos was present in some of the debris at the
site and in areas very close to the site. Between September 28,2001 and August 3,
2002, the vast majority of air sampling results outside the security zone were
below the standards for asbestos in indoor air.
To view the air monitoring results, click on a sampling location below or on the
map (Links will open in a new browser window):
Sampling Site Location
-’•’OJ
1 WestBioadway 19 Vesey and
and Worth Street West Street
o ’
2 Broadway and 20 Vesey
Worth Street between &.. o
Church and
Greenwich
http;//www.nyc.gov/html/dep/html/airmonit.html 8/13/2003
CITY_21MC100_006537352
NYC-WTC_000361761
OCR can misread numbers and units. Confirm readings against the page image before using them.