ASTM D5755 packet, general guidance

Machine-extracted title · confidence 35%

Explaination of designations and update history for ASTM D5755 methods.

NYC-WTC_000361702–000361703
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

1.2/11/2001 l';0S FAI 212 353 8306 ATC @004

(Sib Designation: D 6755 - 95 AVERICA/I SOCIGTV POU TeiTlNO knO MAtewALS 1110 PNIMtlOhiA P» 1»'0J Atprinlrt Irani IM Anr»«l Soo* ol ASW Sunaordt Coer'S'* A5TM (I ™i tetod In M currtm combined Indo*, «« opM*' " lh» Mid odlon

Standard Test Method for Microvacuum Sampling and Indirect Analysis of Dust by Transmission Electron Microscopy for Asbestos Structure Number Concentrations'' This U Issued under ihc fixed designiiinn 0 5755; the number immcdiitcly fo(Io'*irn th: destnation indicates the year of original adoption or. in Iha case of revision, the yeu oriin revision. A number in parentheses indicates the year of Iasi reapproval. A Supencripi epsilon (■) Indicates an adiloriul change since the list revision or reaporovjl,

I. Scope responsibility of the user of this standard to establish appro­ 1.1 This test method covers a procedure to (n) identify priate safely and health practices and determine the applica­ asbestos in dust and (b) provide an estimate of the concen­ bility of regulatory limitations prior to use. tration of asbestos in the sampled dust reported as the number of asbestos structures per unit area of sampled 2. Referenced Documents surface. 2.1 ASTM Standards: l.I.l If an estimate of the asbestos mass is to be deter­ D 1193 Specification for Reagent WateP mined. the user is referred to Test Method D 5756. D 1739 Test Method for the Collection and Measurement 1.2 This test method describes the equipment and proce­ of Dustfall (Scttlcablc Particulate Matter)’ dures necessary for sampling, by a microvacuum technique, D 3195 Practice for Rotameter Calibration’ non-airborne dust for levels of asbestos structures. The D 3670 Guide for Determination of Precision and Bias of non-airborne sample is collected inside a standard filter Methods of Committee D-22’ membrane cassette &om the sampling of a surface area for D5756 Test Method for Microvacuum Sampling and dust which may contain asbestos. Indirect Analysis of Dust by Transmission Electron 1.2.1 This procedure uses a microvacuuming sampling Microscopy for Asbestos Mass Concentration’ technique. The collection efficiency of this technique is unknown and will vary among substrates. Properties influ­ 3. Terminology encing collection efficiency include surface texture, adheave- 3.1 Dejtnitions: nejs. electrostatic properties and other factors. 3.1.1 asbestiform—a special type of fibrous habit in which 1.3 Asbestos identified by transmission electron micros­ the fibers are separable into thinner fibers and ultimately copy (TEM) is based on morphology, selected area electron into fibrils. This habit accounts for greater flexibility and diffraction (SAED), and energy dispersive X-ray analysis higher tensile strength than other habits of the same mineral. (EDXA). Some information about structure size is also For more information on asbeshform mineralogy, see Refs determined. (I)." (2) and (3). 1.4 This test method is generally applicable for an esti­ 3.1.2 asbestos—-2. collective term that describes a group of mate of the concentration of asbestos structures starting from naturally occurring, inorganic, highly fibrous, silicate domi­ approximately l(X30 asbestos structures per square centi­ nated minerals, which are easily separated into long, thin, metre. flexible fibers when crushed or processed. 1.4.1 The procedure outlined in this test method employs ap indirect sample preparation technique. It is intended to Discussion—Included in the definition an the ssbesdfonn varieties disperse aggregated asbestos into fundamental fibrils, fiber of; setpentine (chrysotile); riebeckite (croddoUte); grunerite (grunerite ashestosk antbophylHte (anthophyllite labestosh ttonoliic (tremolite bundles, clusters, or matrices that can be more accurately ashcaea); and actinolife (ininolite asbentn). The aoiphibolc mineral quantified by transmission electron microscopy. However, as eoopodtioiu are defined according to nomeQClaiure of the laieraa- with all indirect sample preparation techniques, the asbestos tiooal Mineralogical Axsodation (3). observed for quantification may not represent the physical Asbestos OKmial Abnraei Serrin Na.’ form of the asbestos as sampled. More specifically, the Chrysolite 12001-29-5 procedure described neither creates nor destroys asbestos, CroddoOte I2OOI-3M but it may alter the physical form of the mineral fibers. Crunente Asfaestos 12172-73-5 AAtlMpliytlits AihettM 77S35-S7-S 1.5 The values stated in SJ units are to be regarded as the TiESBalite Adxstos 77536-SS-# standard- The values given in parentheses are for informa­ AeiiBoliie Aibcsioi 775J<-«-4 tion only. 3.1.3 Jibril—a single fiber that cannot be separated into 1.6 This statuiard does not purport to address all of the safely concerns, if any, associated with Its use. Il is the ^Annual Book <iASTM Stimbai}. Vol 11.01. > Aimual Boot a/ASTU Sumdanix. Vol 11.03. ' Thif lol inciiiod n under the jiuudiciien of ASTM Commiitcc D.22 on ‘ The boUraec numben ia jxrenibcia refer to the lia of reraeoca at the end Ssmpluic and AnaJyas of Aimcaphoo and o Oie direcl roDoniibiKly of of this td BKlhod. Subromminoc D22.07 an Saitielin* end AnolreJ of AjboUU. 'The non-ubeflifonn varntians of the miaenb indlcaled in 5.13 hove Cutrtnl odiiion appravod Auimi 15. 1995. Published October 1995. dllfctml Chnnical Abonct Service (CASI numbers.

1

CITY_21MC100_006537262

NYC-WTC_000361702

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000361702Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →