NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

ASTM D5755 dust analysis methodology

Machine-extracted title · confidence 37%

ASTM D5755-95 procedure for dust analysis by TEM/PLM in asbestos assessment.

NYC-WTC_000361699–000361700
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

1^ Designation: D 5755 - 95 AMEBICWI SOCISTY POFt TIJTINO AND MATCItlALS mo ruev 51 Piwaaelphia, Pv l»10J Acprinlcd (.ora IM Ar.nu.1 BpO* pl ASTM Sund.<d>. Copyt^nt A5TM Il notK,»alnir» cu.ivAtcoP'WnKiiniiBi will Appear mthv MAI vplcn

Standard Test Method for Microvacuum Sampling and Indirect Analysis of Dust by Transmission Electron Microscopy for Asbestos Structure Number Concentrations'' This sUnCtinJ Issued unda itie fixed designation 0 5755; the number immediately rDllo»int the designation indicates the year of original adoption or. in the case of revision, the year of Un revision. A number in percnihcscs indicates the year of last reapproval. A Su perse ri pl epsilon r r) indicates an udilortal change since the last revision or reaporov-jl

I. Scope responsibility of (he user of this standard io establish appro­ 1.1 This test mcihod covers a procedure to (a) identify priate safety and health practices and determine the applica­ asbestos in dust and (i) provide an estimate of the concen­ bility of regulatory limitations prior to use. tration of asbestos in the sampled dust reported as the number of asbestos structures per unit area of sampled 2. Referenced Documents surface. 2.1 ASTM Standards: 1.1.1 If an estimate of the asbestos mass is to be deter­ D1193 Specification for Reagent Water’ mined, the user is referred to Test Method D 5756. D 1739 Test Method for the Collection and Measurement 1.2 This test method describes the equipment and proce­ of Dustfall (Scttlcablc Particulate Matter)^ dures necessary for sampling, by a microvacuum technique, D3I9S Practice for Rotameter Calibration’ non-airbome dust for levels of asbestos structures. The D3670 Guide for Determination of Precision and Bias of non-airbome sample is collected inside a standard filter Methods of Committee D-22’ membrane cassette from the sampling of a surface area for D5756 Test Method for Microvacuum Sampling and dust which may contain asbestos. Indirect Analysis of Dust by Transmission El^on 1.2.1 This procedure uses a microvacuuming sampling Microscopy for Asbestos Mass Concentration’ technique. The collection efficiency of this technique is unknown and will vary among substrates. Properties influ­ 3. Terminology encing collection efficiency include surface teitture, adhesive­ 3.1 Definitions: ness, electrostatic properties and other factors, 3,1.1 asbestiform—a special type of fibrous habit in which 1.3 Asbestos identified by transmission electron micros­ the fibers are separable into thinner fibers and ultimately copy (TEM) is based on morphology, selected area electron into fibrils. This habit accounts for greater flexibility and diffraction (SAED), and energy dispersive X-ray analysis higher tensile strength than other habits of the same mineral. (EDXA). Some information about structure size is dso For more information on asbestiform mineralogy, see Refs determined. (J)," (2) and (3). 1.4 This test method is generally applicable for an esti­ 3.1.2 asbestos-^a. collective term that describes a group of mate of the concentration of asbestos structures Starting from naturally occurring, inorganic, highly fibrous, silicate domi­ approximately 1000 asbestos structures per square centi­ nated minerals, which are easily separated into long, thin, metre, flexible fibers when crushed or processed. 1.4.1 The procedure outlined in this test method employs an indirect sample preparation technique. It is intended to Discussion—Included in the definition are the lahestifona varieties disperse aggregated asbestos into fundamental fibrils, fiber oft serpentine (chrysotile); riebeckjie (croddoliteX grunerite (grunerite Bshestos): anthophyllite (anthophyliite asbestos^ tremolite (tremolite bundles, clusters, or matrices that can be mote accurately arfaesun^ and actinoUtt (actinoUte asbestos). The amphibole mineral quantified by transmission electron microscopy. However, as comporitionf are defined acconfiog lo nomeodarure of the Interna­ with all indirect sample preparation techniques, the asbestos tional Mineralogical Association (3), observed for quantification may not represent the physical AAoloe Owmlcal Absinct Service No.’ form of the arixatos as sampled. More specifically, the ChrytoliJc 12001.294 procedure described neither creates nor destroys asbestos, OoculoQtt I200I-2S4 but it may after the t^yrical fonn of the mineral fibers. CnineriSc Asbesto] 12172-73-5 Aathaohyiliia Asbestea 77536-67.$ 1.5 The values stated in SI units are to be regarded as the Treniolilc Asbcslos 77536-614 standard. The values given in parentheses arc for infonna- Actinolite Aibtaw 7753lS46-« tion only. 3.1,3 fibril—^ single fiber that cannot be separated into 1.6 Thu staiuieni detej not purport to euidrers all of the safety concerns, if any, associaied with its use. It iS the ^AimialBoak StanJanb. Vol 11.01. ^AMOudBaA^A^rUSiaidanb. Vol 11.01. ' Thi» lest melhod a under the juiiidicuoB of ASTM Committee 0-22 on < The boldf»ee numbej io p«renihe»e» refer ta the lia of rtferenoei at ibe end Samplinc end Afvlyn of Atmenpliera and is the diteet lesoofaibiUir of of Ihir test EBetbod. Sub D22.07 OB Siunplijn Bod Arabp* of Asbote*. '"nie non-aabetifonn variaiion* «f the minenhi indicated in 5.1 J ha-e Cumm attlioB Aunut 15. 1955. PuWbhed October 1995. diirctenl Chemical Ahstrict Service (CaS) nutnbcri.

1

.11

CITY_21MC100_006537256

NYC-WTC_000361699

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000361699Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →