NYC-WTC_000387917
Notice of PCM asbestos analysis results for Warren & [name], with report showing fiber counts.
2 shared non-person entities · 1 shared topics · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗Summary table of TEM asbestos analyses for 31 samples related to PS 89 project.
NYC-WTC_000361679
OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
SCIBNnm LAB0llAmilBS, IMC. SCILAB 117 EAST 30TH STREET NEW YORK, NY 10016 FULL SER VICE ENVIRONMEfITAL LABORATORIES TEL: (212) 679-8600 • FAX: (212) 679-9392
October 6,2001
Warren & Panzer Engineering, P.C. Attn: Fabio Pedone 228 East 45th Street 10th Floor New York, NY 10017
RE: Warren & Panzer Engineering, P.C. Job Number 201101437 P.O. # 1017.17.01 1017.17.01; D.D.C.; P.S. 89 201 Warren Street
Dear Fabio Pedone:
Enclosed are the results for TEM asbestos analysis of the following Warren & Panzer Engineering, P.C. samples received at Scientific Laboratories on Friday, October 05,2001, for a 24 hour turnaround:
1, 2, 3,4, 5, 6, 7, 8. 9, 10, 11, 12, 13,14, 15,16,17, 18, 19, 20, 21,22,23, 24, 25, 26, 27, 28, 29, 30, 31
The 31 air samples were sent to SciLab via Hand Delivered. These samples were prepared and analyzed according to AHERA Protocol as contained in 40 CFR, Part 763, Subpart E, Appendix A.
Table I represents a summary of all pertinent information used for the structure (fiber) density and concentration calculations. Included are the size of each structure counted, the structure density and concentration, type of asbestiform material detected and the analytical sensitivity, which represents the concentration by the detection of one structure in the TEM structure count. Copies of the Asbestos Count Sheets are included. These data sheets contain information for structure (fiber) length/width, structure type, structure morphology and pertinent information on EDS, SAED and photography.
This report relates ONLY to the sample analysis expressed as structure density. SciLab assumes no responsibility for customer supplied data such as “sample location” or “air volume sampled”. This report must not be used to claim product endorsement by SciLab, NVLAP or any agency of the U. S. Government. The National Institute of Standard.? and Technology Accreditation requirements, mandates that this report must not be reproduced, except in full without the approval of the laboratory. i 1
SciLab appreciates this opportunity to serve your organization. Please contact us for any further assistance or questions.
SincerelYl
Laboratory Director
NEW YORK • LOS ANGELES • SAN FRANCISCO • BOSTON • ALBANY • RICHMOND
CITY_21MC100_007143307
NYC-WTC_000361679
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000387917
Notice of PCM asbestos analysis results for Warren & [name], with report showing fiber counts.
2 shared non-person entities · 1 shared topics · similarity 0.933
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000390829
R.K.M. Inc samples asbestos analysis report with TEM results; November 2001.
2 shared non-person entities · 1 shared topics · similarity 0.935
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000345215
TEM AHERA asbestos analysis results for NYC DEP project, June 2002.
1 shared non-person entities · similarity 0.932
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000345206
TEM TEM analysis results for NYC DEP project, June 2002, TEM method.
1 shared non-person entities · similarity 0.929
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000345123
Asbestos TEM analysis results; data transmitted for NYC-DEP W&P file.
1 shared non-person entities · similarity 0.928
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000345116
TEM analysis of air samples for NYC DEP site clearance; results attached.
1 shared non-person entities · similarity 0.927
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000344360
TEM asbestos analysis report for NYC DEP project 8327, June 29, 2002.
1 shared non-person entities · similarity 0.923
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000344408
TEM asbestos analysis results for 8461, AHERA, 2002.
1 shared non-person entities · similarity 0.921
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000343144
Table I summary of TEM asbestos results for air at NY Law School facilities.
2 shared non-person entities · similarity 0.921
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000095173
Applied Technology Services Inc. submits a comprehensive report on ambient air and bulk sampling for the New York County Law Association.
1 shared non-person entities · 1 shared topics · similarity 0.921
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000344504
Asbestos fiber analysis by TEM performed for NYC DEP W&P project file 1079.01.02.
1 shared non-person entities · similarity 0.921
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000205958
Laboratory results for asbestos fiber analysis by transmission electron microscopy at 125 Cedar Street conducted in late June 2002.
1 shared non-person entities · similarity 0.921
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000390829
R.K.M. Inc samples asbestos analysis report with TEM results; November 2001.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000387917
Notice of PCM asbestos analysis results for Warren & [name], with report showing fiber counts.
Similarity score 0.967 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000094546
Chain of custody form for asbestos samples commissioned by the building management at 211 West Broadway.
Similarity score 0.962 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000347395
TEM asbestos analysis report for NYC DEP project W&P# 1079.01.02, results dated 7/21/02.
Similarity score 0.960 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000364646
Results for TEM asbestos analysis of multiple SCILAB samples; October 30, 2001 delivery.
Similarity score 0.960 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000124304
Laboratory report from ATC Associates providing transmission electron microscopy results for air samples collected at 99 Church Street.
Similarity score 0.959 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000390829
R.K.M. Inc samples asbestos analysis report with TEM results; November 2001.
Similar indexed content
NYC-WTC_000387917
Notice of PCM asbestos analysis results for Warren & [name], with report showing fiber counts.
Similar indexed content
NYC-WTC_000345215
TEM AHERA asbestos analysis results for NYC DEP project, June 2002.
Similar indexed content
NYC-WTC_000345206
TEM TEM analysis results for NYC DEP project, June 2002, TEM method.
Similar indexed content
NYC-WTC_000345123
Asbestos TEM analysis results; data transmitted for NYC-DEP W&P file.
Similar indexed content