Air sample results summary, Week of 02/15/02, ATC

Machine-extracted title · confidence 37%

Air sample results summary for 02/15/02–02/22/02 at World Trade Center site, showing exceptions above OEL.

NYC-WTC_000361355
Page image
Scanned page image, NYC-WTC_000361355
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

liberty Mutual.

Industrial Hygiene Air Sample Results Summary for Week of 2/15/02 to 2/22/02

Attached is a summary of the laboratory results and direct reading measurements completed during the week of February 15, 2002 to February 22, 2002. The air samples were collected and the measurements made by ATC associates at the World Trade Center site.

The majority of the samples collected by ATC are “personal samples”, meaning that the worker wore the sampling device. Most of results have shown exposure levels to be below shift adjusted occupational exposure limits. The exceptions were;

• Quartz concentration of 733%, 237%, and 179%of the shift adjusted OEL on three tie-back hole drillers in WTC 6. • Quartz concentration of 625% of the shift adjusted OEL on a laborer at SW section of slurry wall. • Quartz concentration of 114 % of the shift adjusted OEL on Core driUer at WTC 6 Level B2. • Quartz concentration of 110 % of the shift adjusted OEL on spotter in Depression between N Tower & S Tower. • Lead concentration over 1500 % and Arsenic concentration of 278% of the shift adjusted OEL on a Torch Cutter in Depression North from Tower 2.

In addition, the following results are at or above 50% of the shift adjusted OEL (but below 100% of the shift adjusted OEL). The operations associated with these results should receive attention to ensure that these results are an accurate reflection of actual exposures and that feasible steps are taken in an attempt to ensure that exposures do not elevate over time;

• Asbestos concentration of 76 % of the shift adjusted OEL on IH tech Walking all Ground Zero Work Areas. • Asbestos concentration of 66 % and 54 % of the shift adjusted OEL on grappler operator in depression at 5 WTC. • Asbestos concentration of 64 % of the shift adjusted OEL on Torch cutter in depression south of tower #1. • Asbestos concentration of 60 % of the shift adjusted OEL on operator in depression Eofl WTC. • Asbestos concentration of 58 % of the shift adjusted OEL on spotter in depression Tower #1 & 2. • Quartz concentration of 83 % of the shift adjusted OEL on Dnller at 6 WTC Level B2. • Iron concentration of 82 % of the shift adjusted OEL on Torch Cutter in Depression North from Tower 2.

Some of the columns in the attached summary may require explanation:

CITY_21MC100_002845742

NYC-WTC_000361355

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000361355Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →